Homa Sanistar 1 Series Installation And Operation Instruction Manual Download Page 11

11 

 

 

Contents 

 

Contents Page 

  1.    EC Declaration of Conformity 

11 

  2.    Safety Warnings 

12 

  2.1. General instructions 

12 

  2.2. General Safety Precautions 

12 

  3.    Applications and Technical 
         Description 

12 

  3.1. Applications 

12 

  3.2. Product Description 

12 

  3.3. Technical Data 

13 

  3.4. Operation Conditions 

13 

  3.5. Explosive Environments 

13 

  4.    Warranty 

13 

  5.    Transport and Storage 

13 

  6.    Electrical Connection 

13 

  6.1. General instructions 

13 

  6.2. Electronic control box 

14 

  6.3. Check of Direction of Rotation 

15 

  7.    Installation 

15 

  8.    Start-Up 

15 

  9.    Maintenance and Repair 

16 

10.    Fault Finding Chart 

16 

11.    Warranty Conditions and Warranty  
         Receipt 

17 

13.    Installations 

18 

14.    Dimensions 

18 

15.    Spare Part List and Drawings 

20 

15.1. Spare Part List Collecting Tank 

20 

15.2. Spare Part Drawings Collecting Tank 

20 

15.3. Spare Part List Pump 

21 

15.4. Spare Part Drawings Pump 

22 

16.    Order Sheet for Spare Parts 

23 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

1. Declaration of Conformity 

 

EC Declaration of conformity in line with the EC Ma-
chinery Directive 89/392/EEC, Appendix IIA 
 
We, HOMA Pumpenfabrik GmbH, Industriestrasse 1,  
D-53819 Neunkirchen-Seelscheid, hereby declare that in 
respect to their design and construction the following 
pump types, in the form in which they are marketed by us, 
conform to the relevant fundamental safety and health 
requirements of the EC Machine Directives...: 
 

 

 

 Sanistar 

 

 
EC-Directives to which the pumps conform: 
EC Machinery Directive 

89/392/EEC dated 1989 

as amended 

91/368/EEC dated 1991 

as amended 

93/  44/EEC dated 1993 

as amended 

93/  68/EEC dated 1993 

EC Directive, electromagne-
tic compatibility 

89/336/EEC dated 1989 

as amended 

92/  31/EEC dated 1992 

as amended 

93/  68/EEC dated 1993 

EC Low Voltage Directive 

1)

 

73/  23/EEC dated 1973 

EC Directive, explosion-
proofed operating material 

2)

 

79/196/EEC dated 1979 

as amended 

84/  47/EEC dated 1984 

as amended 

88/571/EEC dated 1988 

 
Relevant harmonized industrial standards 
ES 60335-2-41 

1)

 ES 

60335-1 

1)

  ES 60034 Part 5 

ES 60204 Part 1 

1)

  ES 50081-1 

ES 50082-1 

ES 55014 

ES 55104 

ES 60555-2 

ES 60555-3 

ES 292 

ES 50014/18/19/20 

2)

 

 
Specially applied national standards and technical 
specifications (other applied standards for general 
mechanical engineering are deposited at the const-
ruction office):
 
ISO 2548 

DIN 24250 

DIN 19760 

1)

 

 
 
 
 
 
 

(Dr. Klaus Hoffmann, Management) 
01.04.2000    HOMA Pumpenfabrik GmbH 
 

1)

 does not apply to Ex models 

2)

 only applies to Ex models 

 
 
 
 
 
 
 
 
 
 
 

Established:     Totzke  Index: 

            0 

Date: 

01.01.1998 

Current number:     CE  1

 

 

Summary of Contents for Sanistar 1 Series

Page 1: ...e und Bedienungsanleitung Installation and Operation Instruction Manual Montage en Bedrijfsinstructies Abwasser Hebeanlage Compact sewage disposal unit Afvalwater opvoerinstallatie Baureihe Series San...

Page 2: ...e 18 Pagina 18 Seite 20 Page 20 Pagina 20 DEUTSCH ENGLISH NEDERLANDS Installationsbeispiele Installations Installatievoorbeelden Bauma e Dimensions Afmetingen Ersatzteilliste und Ersatzteilzeichnungen...

Page 3: ...owie in der von uns in Verkehr gebrachten Ausf hrung den einschl gigen grundlegenden Sicherheits und Gesundheitsanforderun gen der EG Maschinenrichtlinien entsprechen Bei einer nicht mit uns abgestimm...

Page 4: ...r Ger t verur sacht werden wenn die Hinweise und Vorschriften aus dieser Bedienungsanleitung nicht eingehalten werden nicht haften F r Zubeh rteile gelten die gleichen Be stimmungen 3 Einsatz und Tech...

Page 5: ...sschlie lich explosionsgesch tzte Ausf hrungen eingesetzt werden Die Explosionsschutzklasse der Pumpen muss in je dem Einzelfall von den Beh rden f r den Montageort zu gelassen werden 4 Garantie Garan...

Page 6: ...oranlauf erzeugt dies einen Ruck des Motors entgegen dem Uhrzeigersinn Zur Vertauschung der Phasen bei falscher Phasenfolge siehe unter Punkt 6 3 Gr ne LED Betrieb Leuchtet wenn die Pumpe arbeitet Rot...

Page 7: ...r eine der gr nen Betriebs LED rufen Sie bitte unseren Kundendienst HOMA ServCom Contoller zum Programmieren und Abrufen von Betriebsdaten als Zubeh r erh ltlich 6 3 Phasenvertauschung Bei 1Ph Motoren...

Page 8: ...isierten Fachwerkstatt durchgef hrt wurden oder wenn bei einem Teileaustausch keine ORIGINAL ERSATZTEILE verwendet wurden nicht haften F r Zu beh rteile gelten die gleichen Bestimmungen Vor jeder Arbe...

Page 9: ...atzbedingungen mangelnde Pflege oder unsach gem e Reparaturversuche zur ckzuf hren sind sind von der Garantie ebenso ausgeschlossen wie normaler Verschlei Hier durch entstandene Kosten insbesondere be...

Page 10: ...ttrum 0 42 64 12 50 Ritz GmbH Carl Zeiss Str 33 79761 Waldshut Tiengen 0 77 41 48 80 Pumpen Binek Kirchsteig 2 31275 Lehrte 0 51 36 89 30 37 Wolfgang B rk Forststr 17 79618 Rheinfelden 0 76 23 75 21 0...

Page 11: ...pect to their design and construction the following pump types in the form in which they are marketed by us conform to the relevant fundamental safety and health requirements of the EC Machine Directi...

Page 12: ...accessories 3 Applications and Technical Description 3 1 Applications HOMA disposal units Sanistar are used for pumping waste water effluent or groundwater containing sludge or soft solids from rooms...

Page 13: ...nd stored in vertical or horizontal position Make sure that it cannot roll or fall o ver For longer periods of storage the unit should be pro tected against moisture frost or heat 6 Electrical Connect...

Page 14: ...e LED Failure the pump was stopped by thermal cutout In this case push the Reset switch If the pump still does not work please contact your HOMA service Red LED Failure Flash Signal The Failure LED fl...

Page 15: ...in the discharge pipe the pipe and the liftimg station should be dimensioned for a water velocity of minimum 0 7 m s for vertical pipes however not lower than 1 0 m s The incoming sewer could be ensu...

Page 16: ...y is watertight and that the cables are not bent sharply and or pinched Pump parts Check for possible wear Replace defective parts Ball bearings Check the shaft for noisy or heavy opera tion turn the...

Page 17: ...eated by a streng tech nical end control before delivery If the unit still gives an occasion for a legitimated complain you have the claim of an appropriated correction free of charge Warranty repairs...

Page 18: ...mpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid verklaren hiermee dat de opvoerinstallatie Sanistar op grond van hun concipi ring en bouwwijze als ook in de door ons in verkeer gebra...

Page 19: ...en Wij wijzen erop dat wij volgens de product aanspra kelijkheidswet niet aansprakelijk zijn voor schade welke door onze machines veroorzaakt worden wanneer de aanwijzingen en voorschriften uit deze g...

Page 20: ...gevaar Gebruik in explosiegevaarlijke omgevingen alleen de explosie vrije uitvoeringen In alle gevallen dient de plaatselijke instantie te bepalen of de explosieclassificatie van de pomp voor de gewen...

Page 21: ...fasen bij verkeerde fasevolgorde zie punt 6 3 Groene LED Betrieb Brand wanneer de pomp in werking is Rode LED St rung Continu signaal in verbinding met LED Alarm Branden st rung en alarm LED beiden c...

Page 22: ...e aanbevolen jaarlijkse onderhoudstermijn is bereikt Het signaal wordt door de servicedienst na onderhoud gereset Onderhoudssignaal deactiveren De bedrijfsschakelaar in stand Aus Off zetten en aanslu...

Page 23: ...naar de buitenlucht te worden geleid Bevestig de meegeleverde aangesloten pomp besturing in overeenstemming met de in Nederland Belgi geldende richtlijnen tegen de wand De kabel tussen motor en bestu...

Page 24: ...lokkeerd Aanvoer afsluiten Reservoir met handpomp leegpompen Reinigingsopening openschroeven en het reservoir met de hand legen en eventuele vaste delen in het medium verwijderen Drukslang van de nive...

Page 25: ...trenge technische eindcontrole Mocht het apparaat desondanks reden tot een gerechtvaardige garantieclaim geven dan heeft u recht op een aansprekende kostenloze afwerking Garantiereparaties mogen allee...

Page 26: ...ect connection Euro WC inlet height 180 mm Direkt aansluiting Euro WC toeloophoogte 180 mm Direktanschluss H nge WC Zulaufh he 250 mm Direct connection hanging WC inlet height 250 mm Direkt aansluitin...

Page 27: ...Verticale inlaat DN 100 DN 40 6 Anschlu f r pneumatische Steuerung Connection for pneumatic control box Aansluiting pneumatische besturingskast 7 Entl ftungsstutzen DN 70 Air vent DN 70 Ontluchting DN...

Page 28: ...cription Pos Part description 1 01 Collecting tank 4 06 PVC hose 1 02 Countersunk hexag socket screw 5 01 Rubber fabric hose 1 03 Washer 5 02 Hose band 1 04 Fastener 6 01 Flanged spigot 3 01 Valve hou...

Page 29: ...27 xx Knickschutzt lle 360 Lagerdeckel 834 xx Kabeldurchf hrung 410 Dichtklappe 835 xx Motoren Klemmbrett 411 xx Dichtring 836 xx Klemmleiste 412 xx O Ring 837 Betriebskondensator 420 Wellendichtring...

Page 30: ...the motor cooling jacket 932 xx Circlip 704 Threaded tube for the motor cooling jacket 940 Fitting key 719 Shrink down plastic tubing 950 Ball bearing disc 720 90 discharge elbow 970 Pump label 721 ST...

Page 31: ...31 15 4 Ersatzteilzeichnung Pumpe Spare part drawing pump Onderdelenlijst Pomp Sanistar 110 W D Sanistar 210 W D Sanistar 120 W D Sanistar 130 D Sanistar 220 W D Sanistar 230 D...

Page 32: ...Nr Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 16 Order Sheet for Spare Parts To HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47 7 02 44 Pump type see pump label Y...

Page 33: ...1 183 622212 Fax 31 183 620193 Pomp type zie typeplaatje Bouwjaar zie typeplaatje Gedetailleerde onderdelen 1 Pos nr Omschrijving Aantal 2 Pos nr Omschrijving Aantal 3 Pos nr Omschrijving Aantal 4 Pos...

Page 34: ...___________ ______________________________ ______________________________ ______________________________ ______________________________ ______________________________ ______________________________ __...

Page 35: ...35...

Page 36: ...36...

Reviews: