The controller of Sanistar automatically ensures an even 
distribution of operating hours on both pumps by changing 
the starting sequence after each pump stop. 
When the liquid level in the tank reaches the start level, 
one pumps is started. If the liquid level rises further, the 
other pump is started as well. Both pumps will stop,  
when the lowest stop level is reached.If the liquid level 
continues to rise when both pumps are operating, an 
alarm is given until the liquid level is lowered below the 
alarm level. 
 
The installation kit consists of a discharge connector, a 
pipe and a non-return valve.  

 

3.3. Technical Data 

Inlet 

3 x DN 100  

Connection for aurvent, cable duct 

DN 70 

Discharge 

BSP 1 ¼" M 

Tank volume 

40 l 

Insulation class 

Motor protection 

IP 68 

Max. liquid temperature 

35°C, short term up 
to 60°C 

Speed 2.900 

rpm 

 

Applicable pump models 

Pump type 

Motor  

P

1

 (kW) 

Voltage 

50 Hz (V) 

Nominal 

current (A)

Weight

(kg) 

C 235 W 

0,35 

230-240/1Ph 

1,8 

4,6 

C 290 W 

1,20 

230-240/1Ph 

5,0 

8,3 

C 290 D 

1,10 

400-415/3Ph 

2,0 

8,3 

CR 360 VW 

0,63 

230-240/1Ph 

2,9 

6,9 

TP28 VW 

1,10 

230-240/1Ph 

5,6 

22 

 

3.4. Operation Conditions

 

Please pay attention to the installation and operation 

instruction manual of the installed submersible pump. 

 
3.5. Explosive Environments

 

For operation of the pumps in explosive environments 

only models with explosion-proof motors (Ex model) must 
be used. 

For each individual installation the explosion classifi-

cation (Ex-class) of the pump must be approved by the 
localauthorities. 

 
4. Warranty 

Our warranty only covers pumps which are installed and 
operated in accordance with these installation and opera-
tion instructions and accepted codes of good practice and 
being used for the applications mentioned in these  
instructions. 
 

5. Transport and Storage

 

 The pump station may be transported and stored in 

vertical position. Make sure that it cannot roll or fall over. 
For longer periods of storage, the pump should be pro-
tected against moisture, frost or heat. 
 
 
 
 
 

6. Electrical Connection 

6.1. General instructions 

Before operation, an expert check must secure that 

the required electrical protection measures exist. The 
connection to ground, earthing, isolating transformer, fault 
current breaker or fault voltags circuit must correspond to 
the guidelines set forth by the responsible power plant. 

The voltage required in the technical data sheet 

must correspond to the existing line voltage. 

Make sure that the electrical pin-and-socket connec-

tions are installed flood- and moisture-safe. Before start-
ing operation check the cable and the plug against dam-
ages. 

The end of the pump power supply cable must not be 

submerged in order to prevent water from penetrating 
through the cable into the motor. 

 

The electrical connection of the pump should be carried 
out in accordance with local requirements. 
The operating voltage and frequency are marked on the 
pump and controller nameplates. Voltage tolerance: +6% 
up to -10% of the voltage stated on the nameplates. Make 
sure that the pumps of the pump station are suitable for 
the electricity supply available at the installation site. 
 
In case of a defect of the pump, a repair shall be carried 
out only by the manufacturer or through an authorized 
workshop. Modifications of the pump must be confirmed 
by the manufacturer. 
 
Controlb box and pump have to connect as shown in the 
wiring diagram in the manual instruction of the pump.  
 
The electrical connection must be carried out in accor-
dance with the marking on the cable to the controller. 
Connect the units to the mains supply. 
An external fault signal device can be connected to the 
controller via the potential-free fault signal output.  
Maximum load: AC 250 V, 5 A, AC 1. 

Motor-Start 

The motor of units are designed for direct-on-line (DOL) 
start. 
 

6.2. Electronic control box 

The equipped electronic control box controls the operation 
functions and announce failures which may be occure. 
 

Operation switch (one of each pump) 

Postion "Manu" 

The pump operates, irrespective of the liquid level in the 
tank. To stop the pump release the switch. The switch 
turns into the position „Aus/Off“. 

Position „OFF“ 

The pump is stopped.  

Position "Auto" 

Pump operation according to the liquid level in the tank. 
 

Acoustic alarm switch   

Position "On" 

The built-in acoustic alarm is activated. Together with the 
red LEDs “Alarm“and “Failure“ the built-in acoustic alarm 
will start if the level of the medium is above the alarm 
level. The alarm is automatically reset when the liquid 
level has been lowered below the alarm level. 

 

Summary of Contents for Saniquick UFT Series

Page 1: ...Original Betriebsanleitung Original Instruction Manual HOMA Pumpenfabrik GmbH 02 2011 Industriestr 1 D 53819 Neunkirchen Seelscheid Baureihe Series Saniquick UFT...

Page 2: ...chten Ausf hrung den einschl gigen grundlegenden Sicherheits und Gesundheitsanforderun gen der EG Maschinenrichtlinien entsprechen Bei einer nicht mit uns abgestimmten nderung der Produkte ver liert d...

Page 3: ...ienungsanleitung nicht eingehalten werden nicht haften F r Zubeh rteile gelten die gleichen Bestimmungen 3 Einsatz und Technische Beschreibung 3 1 Einsatz der Anlage Die Schmutzwasser Hebeanlage dient...

Page 4: ...etriebes 5 Transport und Lagerung Die Hebeanlage nur in senkrechter Position transpor tieren beim Transport nicht werfen oder st rzen Bei l n gerer Lagerung ist die Anlage gegen Feuchtigkeit W rme ode...

Page 5: ...h nicht einwandfrei arbeitet informieren Sie bitte unseren Kundendienst Rote LED St rung Pumpe 1 Blinksignal Blinkt zur Information 2 Monate bevor der emfohlene j hr liche Wartungstermin erreicht ist...

Page 6: ...nicht abgequetscht wird 7 3 Ein bzw Ausbau von Pumpe und Einbaugarnitur Die Hebeanlage wird als komplette Einheit geliefert Mit Hilfe der berwurfmutter am Sammelschacht kann die Einbaugarnitur und Pum...

Page 7: ...lt werden lsorte biologisch abbaubares HOMA ATOX auf Wunsch lieferbar Verbrauchtes l ist ordnungsge m zu entsorgen Um einen zuverl ssigen und st rungsfreien Betrieb der Anlage sicherzustellen empfehle...

Page 8: ...ingen 03 31 740 40 70 0 74 31 95 83 24 Naumann Pumpen GmbH Co KG G Meier GmbH Am Wall 11 Gustav Schwab Str 16 14979 Gro beeren 72762 Reutlingen 03 37 01 52 50 0 71 21 26 90 0 HEKO Pumpen GmbH Pumpen Z...

Page 9: ...in respect to their design and construction the following products in the form in which they are marketed by us conform to the relevant fundamental safety and health re quirements of the EC Machine Di...

Page 10: ...in the operating instructions The same product liability are valid for accessories 3 Application and technical description 3 1 Application The pump station Saniquick UFT is used for removal of clear w...

Page 11: ...earthing isolating transformer fault current breaker or fault voltags circuit must correspond to the guidelines set forth by the responsible power plant The voltage required in the technical data shee...

Page 12: ...eactivating Maintenance flash is possible starting from version 1 0d of the pump control see menu in ServCom Maintenance flash is deactivated if appears behind in ServCom the version No Maintenance fl...

Page 13: ...eter Pump parts and impeller Check for possible wear Replace defective parts Ball bearings Check the shaft for noisy or heavy opera tion turn the shaft by hand Replace defective ball bear ings A gener...

Page 14: ...rsatzteile An HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 0 22 47 7 02 44 Pumpentyp siehe Typenschild Baujahr siehe Typenschild Detailierte Ersatzteile 1 Pos Nr Bezeichnung Menge 2 Pos N...

Page 15: ...ription Required Quantity 2 Pos no Part description Required Quantity 3 Pos no Part description Required Quantity 4 Pos no Part description Required Quantity 5 Pos no Part description Required Quantit...

Page 16: ...be 6 06 Befestigungslasche 3 03 U Scheibe 7 01 Elektronik Steuerung 4 01 Doppelnippel 8 01 Pumpe 4 02 O Ring 4 03 Einschraubteil 13 Spare part list ATTENTION The following list contains parts that do...

Page 17: ...xisch nein ja welche Stoffe _____________________ tzend nein ja welche Stoffe _____________________ mikrobiologisch nein ja welche Stoffe _____________________ explosiv nein ja welche Stoffe _________...

Page 18: ...______________ corrosive no yes which substance __________________ microbiological no yes which substance __________________ explosive no yes which substance __________________ radioactive no yes whic...

Page 19: ...17...

Page 20: ...18...

Reviews: