CLEANING, MAINTENANCE, STORGAE AND DISPOSAL
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
27
SB163VH
15.1.7
Adjusting the Inclination of the Worktable
The drilling table can be tilted both to the left and to
the right by 45 ° each. To adjust, loosen the nut
below the drilling table with a wrench, adjust the
desired angle and retighten the nut (see picture on
the right).
15.1.8
LED Light
Switch
OFF
or
ON
the working light, as required
15.1.9
Replacing the Drill Bit
Open the drill chuck by turning it counter to direction A
until the drill can be inserted. Hold ring B in place.
Insert the drill bit.
Turn the sleeve of the drill chuck tightly by hand in the
direction of rotation A. Hold ring B in place.
This automatically locks the drill chuck.
16
CLEANING, MAINTENANCE, STORGAE AND DISPOSAL
16.1
Cleaning
N O T E
Wrong cleaning agents can attack the varnish of the machine. Do not use solvents,
nitro thinners, or other cleaning agents that could damage the machine's paint.
Observe the information and instructions of the cleaning agent manufacturer!
Lubricate the machine before initial operation and oil the bare machine parts with an acid-free
lubricating oil. Regular cleaning is a prerequisite for the safe operation of the machine and its
long service life. Therefore, clean the machine after each use, at least once a week. Use a brush,
a hand brush or a vacuum cleaner to remove the chips and drilling dust.
16.2
Maintenance
W A R N I N G
Danger due to electrical voltage! Handling the machine with the power supply up
can lead to serious injuries or even death. Always disconnect the machine from the
power supply before servicing or maintenance work and secure it against
unintentional or unauthorized reconnection!
The machine is low-maintenance and only a few parts have to be serviced. Nevertheless,
malfunctions or defects which could impair the safety of the user must be rectified immediately!
16.2.1
Maintenance Plan
The type and degree of machine wear depend to a large extent on the operating conditions. The
following intervals apply when the machine is used within the specified limits:
Interval
Components
Measure
Before start-up
Safety devices
V-belts
Sicherheitseinrichtungen prüfen
Keilriemen kontrollieren und ggfs. spannen
After start-up
machine;
column and
drilluing table
Clean the machine of chips and drilling dust;
Lubricate the column and drilling table with a thin
layer of oil.
After approx. every 50
operating hours
Taper mandrel
Grease taper mandrel