AN-6130PCIe
HOLT INTEGRATED CIRCUITS
4
The main menu of commands will appear below.
Press “1” to perform a HI-6130 register memory dump. This displays all the HI-6130 system registers
from 0x0000 to 0x0047 which initialize to default values after a master reset. Default values are
specified in the HI-6130 data sheet. Notice the word at address 0x0001 contains 0x8000. This is the
Master Status and Reset Register (0x0001) in the HI-6130. The MSB bit-15 high indicates the HI-6130
READY is high which means the device is ready for the host to access the memory and registers in the
device. See the HI-6130 data sheet for more details on registers and status bit definitions.
The HI-6130 bus controller is initialized with several predefined messages.
Press “5” to command the BC to transmit three (commands) messages to RT address 3. Message 1 is a
Receive command with 32 data words to subaddress SA1 on Bus A, Message 2 is a Transmit command
with 32 data words to SA1 on Bus B and Message 3 is a Receive command with 32 data words to SA1 on
Bus A.