Doc. 12-4091 - r01 (9/12/12)
PG-47
SERVICE
GUIDE
SUPPORT: TOLL-FREE 888-383-DIVE │ FAX 510-729-5115 │ E-MAIL [email protected]
©
2002 DESIGN
(
2012)
NOTE: If the Spring Assembly has seized, broken,
or fails to hold the SCRUBBER BASKET (15) se-
curely against the RED CO
₂
SEAL (28), the Spring
Assembly must be replaced. Otherwise, skip step 6.
6. If removing the Spring Assembly, remove the
LOCK-
NUT (3)
counterclockwise with a 3/8" driver
(Fig. 6)
.
Discard the
LOCKNUT (3)
. Inspect the
SPRING (5)
and
SPRING PAD (4)
for signs of decay, damage, or corro-
sion. Discard if found.
NOTE: The LATCH KEEPER (23) only needs to
be removed if damaged. If it is in good condition
skip step 7.
7. Turning counterclockwise, remove the
SCREWS (24)
using a 5/64" Allen driver
(Fig. 7)
. The
LATCH KEEPER
(23)
should slide free easily.
NOTE: The RETAINER BAND ASSEMBLY (7) only
needs to be removed if damaged or badly corroded.
If it is in good condition skip step 8.
8. Turning counterclockwise with a 3/8" open end
wrench, remove the
LOCKNUTS (14)
and
SCREWS
(13)
from the
BAND ASSEMBLY (7)
(Fig. 8)
. Discard
the
LOCKNUTS (14)
. Then slide the
BAND ASSEM-
BLY (7)
off of the
SCRUBBER BUCKET (1)
.
Fig. 6
Fig. 7