Doc. 12-4091 - r01 (9/12/12)
PG-46
SERVICE
GUIDE
SUPPORT: TOLL-FREE 888-383-DIVE │ FAX 510-729-5115 │ E-MAIL [email protected]
©
2002 DESIGN
(
2012)
NOTE:
Remove the INNER O-RING (25) first; so
it slides easily over the OUTER O-RING (25) with-
out seating in the groove.
4. Remove the
RED CO
₂
SEAL (28) (Fig. 3)
. If less
than twelve months old, inspect the
RED CO
₂
SEAL (28)
for signs of decay. Discard if found. If twelve months or
more old, discard the
RED CO
₂
SEAL (28)
.
5. Inspect the
RED CO
₂
SEAL (28)
groove in the
HEAD
PLATE (27)
for any scratches or damage to the mating
surface. If damaged remove and discard.
Removing Head Plate
a. Turning counterclockwise, remove the
RETAINING SCREWS
(30) and
WASHERS (29)
with a 1/16" Allen driver
(Fig. 4)
.
b. Lift the
HEAD PLATE (27)
off the Scrubber Head.
c. Remove the
O-RING (26)
.
d. Inspect the
O-RING (26)
for wear and deterioration. Discard
if found.
4. Remove the
SCRUBBER BASKET (15)
from the
SCRUBBER BUCKET (1) (Fig. 5)
.
5. Remove the
SPONGE PAD (6)
.
Fig. 3
Fig. 4
Fig. 5