SERVICE
GUIDE
SUPPORT: TOLL-FREE 888-383-DIVE │ FAX 510-729-5115 │ E-MAIL [email protected]
©
2002 DESIGN
(
2012)
3. Disconnect the
BREATHING HOSES (13, 21)
at the
front of each
COUNTERLUNG (30, 44)
by turning the
PLASTIC FITTING NUT (19, 28)
counterclockwise
(Fig.
7)
. Then pull the
PLASTIC ELBOW FITTING (19, 28)
straight out of the
COUNTERLUNG (30, 44) (FIG. 8)
.
Inspect the mating surfaces of the fittings for damage. If
damaged, replace the appropriate parts.
4. Disconnect the
BREATHING HOSES (31, 45)
from
the Scrubber Head by turning the
PLASTIC NUT FIT-
TING (34, 49)
all the way counter clockwise. Then sim-
ply lift the
HOSE (31, 45)
away from the Scrubber Head
(FIG. 9)
. Inspect the mating surfaces of the fittings for
damage. If damaged, repair and replace the appropriate
parts.
4. Unfasten the Velcro BCD Airway Retainer and Har-
ness straps holding the Counterlungs.
5. Disconnect the Quick Releases and Velcro Attach-
ment that connect the top of the
COUNTERLUNGS (30,
44)
to the Counterlung Mounting Yoke, as Shown. In-
spect the Quick Releases and Velcro Fasteners for wear
and damage, repair and replace as needed.
NOTE: The Quick Releases and Velcro Fasten-
ers are sewn in place. In the field the COUNTER-
LUNGS (30, 44) and Counterlung Mounting Yoke
can only be replaced. If shipment to the factory
is possible, contact Hollis Customer Service for
possible repairs of the existing COUNTERLUNG
(30, 44) or Counterlung Mounting Yoke.
6. Turning the
ADV MOUNTING NUT (52)
counterclock-
wise, remove the
ADV/MANUAL DILUENT ADDITION
VALVE (52) (FIG. 10)
. Inspect mating surfaces and the
RUBBER GASKET (53)
for damage. The ADV/Manual
Diluent Addition Valve is not serviceable. If damaged or
faulty, replace with new. Otherwise, follow the PRISM
2 Service and Parts Replacement Schedule (Doc. 12-
4092).
7. Turning the
OXYGEN VALVE MOUNTING NUT
(38)
counterclockwise, remove the
MANUAL OXY-
GEN ADDITION VALVE (38) (Fig. 11)
. Inspect mating
surfaces and the
RUBBER GASKET (39)
for damage.
The Manual Oxygen Addition Valve is not serviceable. If
damaged or faulty, replace with new. Otherwise, follow
the PRISM 2 Service and Parts Replacement Schedule
(Doc. 12-4092).
Fig. 9
Fig. 10
Fig. 11
Fig. 7
Fig. 8