SERVICE
GUIDE
SUPPORT: TOLL-FREE 888-383-DIVE │ FAX 510-729-5115 │ E-MAIL [email protected]
©
2002 DESIGN
(
2012)
6. The final check is to open the
DSV/BOV (1)
. A
brief and sudden rush of air should be observed as the
internal Breathing Loop pressure equalizes with ambient
pressure. Non-occurrence is a sure sign that there is a
leak.
7. If the Breathing Loop has failed this test, repair/re-
place any leaking component found during this test. Re-
peat the test as necessary to find the source of failure.
DISASSEMBLE AND DISINFECT PARTS
1. Follow the proceeding subsection Disassembly to
break down the Breathing Loop.
2. Clean the components with Steramine™ solution.
3. Drain the components, and hang them to dry.