91
2008 IMPERIAL
APPLIANCES — 4
Service
The LP-Gas function of the refrigerator and
LP-Gas pressure will require annual service.
Over time, the BTU rating of the
fl
ame can
change, affecting the refrigerator’s performance.
Ambient temperature, high humidity and altitude
above 5,500 feet can affect performance and
function. If possible, switch mode operation to
AC while at a higher altitude.
NOTE:
Ensure the exterior refrigerator access
panel is properly replaced after removal.
Air in LP-Gas Supply Lines
For safety reasons, the refrigerator will attempt
to ignite on propane gas within a speci
fi
ed
amount of time. When starting the refrigerator
for the
fi
rst time after storage, or after servicing
the gas supply system, propane gas supply lines
may contain air. Due to air in the gas supply
lines, the refrigerator may not ignite on propane
gas within the speci
fi
ed amount of time. Follow
the procedure on how to remove air from the
LP-Gas supply lines.
To remove air from LP-Gas supply lines:
Ensure the primary LP-Gas valve and
any other necessary valves are open.
Try lighting the cooktop burners
fi
rst
to quickly purge air from the main
distribution line.
Push the
ON
/
OFF
button to turn the
refrigerator on.
Press the
MODE
button until the
refrigerator indicates LP. The refrigerator
will start a 30 second trial for ignition
during which the gas safety valve opens
and the igniter sparks.
If the refrigerator fails to light, indicated
by
NO FL
(No Flame)
, turn the
refrigerator
OFF
then back
ON
and set
to
LP mode
. If after the third attempt
the refrigerator fails to light, stop and
consult your local dealer or an authorized
Norcold Service Center.
REFRIGERATOR - RESIDENTIAL (Optional)
The refrigerator operates from shore power,
the generator or the inverter. Thermostat controls
for the refrigerator and freezer temperature are
located inside the refrigerator. The freezer door
has a water and ice cube dispenser. Ice can be
dispensed as crushed or cubed.
NOTE:
The residential refrigerator operates on
120 Volts AC, not from LP-Gas.
Operating refrigerator from inverter
during travel:
Turn the inverter and refrigerator on. The
electrical combination of the engine alternator
and the inverter will supply the power necessary
to operate the refrigerator on 120 Volts AC while
traveling.
NOTE:
Be sure to turn the inverter off after
travel. Hook to shore power to continue
refrigerator operation.
Control Panel
The control panel touch pad illuminates to
indicate when a feature is active. All features
can be manually enabled or disabled by pressing
the touch pad. The light above the touch pad
remains on when a feature is active.
031222
Ensure latches are in
the locked position.
031223
Ensure tabs are inserted.
031224b