123
2008 IMPERIAL
EQUIPMENT — 5
If the slide room does not operate after
checking the safety requirements:
Ensure all electrical connections at the
switch are good.
Ensure the house batteries are fully
charged and the interior house power is on.
Check
fl
uid level in reservoir. Maintain
fl
uid within ½" from top of reservoir
when slide-outs are retracted.
It may be necessary to contact a repair
facility to have the problem diagnosed
and repaired.
Check the two fuses adjacent to the
hydraulic pump. If the fuses are good
and the room does not operate, it is
possible to manually retract the slide.
It may be necessary to contact a repair
facility to have the problem diagnosed
and repaired.
To Move the Slide room manually:
1. Access the slide room hydraulic pump
by removing the interior stepwell
storage tray.
2. Use the ¼" nut driver on the end of the
reservoir cap to turn the release nuts
on the solenoids counterclockwise.
DO NOT
exceed 4½ revolutions as
damage to the solenoids may result.
The room may move slightly when
valves are opened and internal pressure
is released.
3. Line up an equal distance along the
outside wall.
DO NOT
push on the
fl
ange.
4. In synchronized movements, push the
room in with repeated attempts.
5. Close the release nuts when the room is
fully retracted.
NOTE:
The slide room is heavy and will require
several people to push the room into
position. When the slide room is in the
fully retracted position, tighten the
release nuts to hold the room in place.
DO NOT over tighten.
Manual Override - Lippert Electric
The Lippert electric motor operates the
bedroom slide-out.
1. The bedroom slide-out motor is located
under the bed. Lift the bed and remove
the access panel.
2. Turn off the house and chassis battery
disconnect switches (located in rear
curbside bay).
3. Remove 12 Volt DC from the motor by
disconnecting the plug from the slide-
out motor to the power supply.
4. Use a 5/8" wrench to turn driveshaft
and retract room (see illustration).
CAUTION:
Do not continue to turn the motor after
the room is fully extended or retracted.
Damage to the slide mechanism can occur.
5. Once the slide room has been manually
retracted, apply pressure to the wrench
to
fi
rmly set the room. This prevents
room drift.
6. Take the motorhome to an authorized
repair center.
090342h
HWH Slide Motor located under interior entry step.
030750d
Bedroom Slide Motor