APPLIANCES — 4
106
2008 IMPERIAL
Electric Heating Element Status:
Green indicator means the Aqua-Hot is
being heated by 120 Volts AC.
Low Voltage Reset:
The Low Battery
Voltage Fault LED will illuminate. Reset
the Controller by cycling the Diesel
burner switch or inserting a paperclip
into the hole. Press the reset button.
Heating Status:
The Aqua-Hot is being
heated by Diesel or the 120 Volt AC
electric element.
Heating Zones Status:
A thermostat is calling
for heat in a zone.
Normal LED is green.
Red LED means a
short has occurred in
that zone.
Pump Status:
When a pump is
operating, LED is green. A red LED
indicates a short in the pump.
Low Battery Voltage Fault:
Red
LED indicates that battery voltage
is low. Hook to shore power or start
the generator. The Aqua-Hot will not
function until the Electronic Controller is
reset by cycling the Diesel Burner switch
off then back to on, or by inserting a
paperclip or similar tool into the Low
Voltage Reset hole. Press the Reset
button.
Bay Thermostat
A thermostat in the storage compartment turns
on the exchanger in the storage bay to prevent
freezing. The thermostat turns on at 45º F +/- 10º.
Ensure the Aqua-Hot is
ON
when heating the bay.
NOTE:
Turn the Aqua-Hot ON when heating
the bay.
Care & Maintenance
Heat Exchanger
:
Exchangers can be affected by pet hair and
debris causing performance to suffer. The Aqua-
Hot exchangers require a minimum semi-annual
cleaning of the heating
fi
ns, blower fans and
register box. Clean the surrounding area outside
of the exchanger. A vacuum cleaner works well
for this purpose.
Cleaning the register:
Gain access to registers located under sofas,
behind cabinets, or under false
fl
oors, depending
upon the
fl
oor plan. Access is limited. Be cautious
not to puncture coolant lines or register core.
Gently remove retaining screws. Set fans to the
side. Vacuum debris or hair from inside of register.
Use care not to bend or dis
fi
gure
fi
ns on register
core. Vacuum fans then wipe clean with a soft
cloth or paper towel. Reinstall fans and registers.
Clean wood or metal vents in front of heat register
with a soft cloth or vacuum attachment.
Antifreeze:
The antifreeze, a special boiler type propylene
glycol base, has low silicate content with
corrosion inhibitors and heat transfer compounds.
This type of antifreeze provides freeze protection
and excellent heat transfer for operating
ef
fi
ciency. The antifreeze is mixed to a 50/50 ratio
with de-ionized water (water puri
fi
ed by reverse
osmosis).
DO NOT
mix antifreeze types as this
can cause scaling and possible component failure.
The antifreeze can be purchased directly from
Vehicle Systems Inc
.
CAUTION:
Use only a non-toxic propylene glycol
based antifreeze recommended for
boiler applications. This antifreeze
must be affirmed GRAS (Generally
Recognized as Safe by the EPA).
Contact Vehicle Systems Inc. at 1-800-
685-4298 to purchase the antifreeze.