101
e
q
u
Ip
m
e
n
t
-
5
Control Valve:
Each control valve operates a specific slide-
out. The control valve (specific slide-out) is
located by a colored wire on top of the control
valve:
Tan Wire
– Living room slide-out
If Pump Runs:
Disconnect both the house and chassis
disconnect switches.
Access the hydraulic pump.
Ensure that the connection to the
control valve is plugged in. If it is loose
properly secure the connection.
Locate slide-out control valve on pump
by finding the tan wire on top of the
control valve.
Using an Allen wrench insert it into
control valve and turn clockwise (in).
Turn on both the house and chassis
disconnect switches.
Go inside motorhome and press the
slide-out retract button on the Systems
Control Panel. This will retract slide-
out(s).
Disconnect both the house and chassis
disconnect switches.
Using an Allen wrench turn control valve
on hydraulic pump counterclockwise.
Turn on both the house and chassis
disconnect switches.
Take motorhome to an authorized repair
center.
If Pump Does Not Run:
Disconnect both the house and chassis
disconnect switches.
Locate slide-out control valve on pump
by finding the tan wire on top of the
control valve.
Using an Allen wrench insert it into
control valve and turn clockwise (in).
Remove the protective label on the
hydraulic pump. This will access the
manual drive coupler
Attach a standard hex bit into a drill,
cordless or standard.
Insert the hex bit into the coupler found
under the protective label.
Run drill counterclockwise to retract.
Disconnect both the house and chassis
disconnect switches.
Using an Allen wrench turn control valve
on hydraulic pump counterclockwise
Turn on both the house and chassis
disconnect switches.
Take the motorhome to an authorized
repair center.
Manual Override - Bedroom
Depending on floorplan, the bedroom may
have either a cable or an above floor slide-out
system. The above floor slide-out is used when
the bed moves with the slide out. If the closet
moves with the slide-out, the system is cable.
Another method of checking for the cable
system is with bedroom slide-out extended. A
cable is visible under the slide-out.
To Move the Bedroom Slide Room (Above
Floor System) Manually:
Turn off both the battery and house
disconnect switches.
The above floor slide-out motor is
located under the bed. Lift the bed and
remove the access panel.
Disconnect the slide-out motor
electrical plug to remove 12 Volt DC
power from the slide-out motor. The
plug can be located by following wires
that run from the motor to the plug.
Use a wrench to turn driveshaft and
retract room.
Once the slide room is manually
retracted, apply pressure to the wrench
to firmly set the room. This will
prevent room drift.
Take the motorhome to an authorized
repair center.
CAUTION
Do not continue to turn the motor after
the room is fully extended or retracted.
Damage to the slide mechanism can
occur.
030750c
Summary of Contents for 2011 Aluma Lite
Page 10: ...Notes...
Page 42: ...40 Dr ivi ng s afet y 2 Weight Record Sheet...
Page 48: ...46 Dr ivi ng s afet y 2...
Page 72: ...70 e x t e r i o r I n t e r i o r C a r e 3...
Page 140: ...138 w a t e r s y s t e m s 6 Water System Diagram Typical 040487q...
Page 152: ...150 P r o p a n e s y s t e m s 7 Notes...
Page 180: ...178 E l e c t r ic a l s y s t e m s C h a s s i s 9...
Page 185: ...183 C h a s s i s I N f o r m a t i o n 1 0 Weight Record Sheet...