ADJUSTING THE AIRFLOW DIRECTION
Adjusting the vertical airflow direction
Adjust the air direction properly to obtain a higher degree in comfort and to avoid harmful drafts.
The vertical direction of the airflow can be set through the infrared remote control.
VERTICAL AIRFLOW
WARNING
•
The “DIRECTION/SWING” button will be disabled when the air conditioner is not operating.
• Do not operate the air conditioner f
or a long time with the airflow direction set downward in Cooling
and Dry mode; this may cause dripping from the louver inside the room.
•
When the air conditioner is turned on, the motorized louver will start moving 10 seconds later, as
soon as it gets under control of the inner electronics. When the air conditioner is stopped, the motorized
louver will automatically stop in closing position. If the motorized louver malfunctions, it is adviced to
turn off the air conditioner and cut the power for some minutes; then restore the power, turn the Unit
on again and check if the louver works properly.
• Open angle of the hor
izontal louver should not be set too small, as Cooling or Heating performance
may be impaired due to too restricted airflow area.
• Do not operate Unit with hor
izontal louver in closed position.
• Room temperature humidity should be less than 80%.
If the air conditioner operates beyond this limit,
the surface of indoor heat exchanger could get covered with frost: in this case, adjust the louver to the
maximum open angle and select HIGH fan speed.
•
When the air conditioner is connected to power (initial power), the horizontal louver may generate a
sound for 10 seconds: this is a normal operation.
•
To avoid malfunctions, NEVER attempt to move the flaps by hand but always use the remote control for
doing this.
Stop the flaps at your desired position:
Perform this setting while the air conditioner is
operating.
Press the “DIRECTION/SWING" button on
remote control till the desired angle for the
louver is reached. Each time the button is
pressed, the louver moves by 6°.
Automatic SWINGING of the louver:
Perform this setting while the air conditioner is
operating.
Keep pressing the “DIRECTION/SWING”
bu t t o n w i t h o u t r e l e a s i n g fo r m o r e t h a n 2
seconds: the horizontal louver will swing up
and down continuously.
Press the “DIRECTION/SWING” button again
to stop the automatic swinging of the louver.
The inner electronics automatically selects the best position for the louver according to the
operation mode:
• in HEA
TING mode: the flaps are vertically set
• in COOLING mode:
the flaps are horizontally set.
SETTING