-23-
TIMER FUNCTION
COMBINED TIMER
(Setting both ON and OFF timers simultaneously)
TIMER ON/OFF or TIMER OFF/ON function allows you to set the automatic start/stop or stop/start
of the air conditioner at your desired time.
NOTES
TIMER OFF
→
TIMER ON (On
→
Stop
→
Start operation)
This feature is useful when you want to stop the air conditioner after you go to bed, and start it again in
the morning when you wake up or when you return home.
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.
Press the TIMER OFF button.
Press the TIMER OFF button again to display “2.0h”
on the TIMER OFF display.
Press the TIMER ON button.
Press the TIMER ON button again to display “10h” on
the TIMER ON display.
Wait for the remote control to display the setting
temperature.
1.
2.
3.
4.
5.
Example
Example
TIMER ON
→
TIMER OFF (Off
→
Start
→
Stop operation)
This feature is useful when you want to start the air conditioner before you wake up and stop it after
you leave the house.
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.
Press the TIMER ON button.
Press the TIMER ON button again to display “2.0h”
on the TIMER ON display.
Press the TIMER OFF button.
Press the TIMER OFF button again to display “0.5h”
on the TIMER OFF display.
Wait for the remote control to display the setting
temperature.
1.
2.
3.
4.
5.
Stop
On
Set
2 hours later
after setting
Start
10 hours later
after setting
Off
Set
Stop
Start
2 hours later
after setting
5 hours later
after setting
When “TIMER” function is selected, the remote controller automatically sends signals for programmed start & stop to
the Indoor Unit. If you would like to be sure that these signals are received by Indoor Unit, it is necessary to address
the remote controller towards the Indoor Unit’s signal receiver, and check that no obstacles could affect the impulses’
transmission.
CAUTION !
Time increases are 30-minutes’ steps till 10 subsequent hours, and 60-minutes’ steps from 10 to 24 hours.
The remote controller’s Timer is not a clock, so it is necessary to set the time period - not the exact time - for
programmed start/stop.
Unlike operation modes, TIMER settings are not kept in memory by the microcomputer, therefore if a power
failure occurs, TIMER settings will be cancelled and need to be set again.
Before selecting TIMER settings, it is possible to choose your desired operation mode.
TIMER max. range is 24 hours, i.e. it is not possible to operate weekly settings.