20
Operational Selections
geodyna optima
Operator’s Manual
9.8-1
a
b
c
e
f
k
d
g
h
i
m
n
9.8-2
m2
m1
m3
m4
9.8-3
n3
n4
n2
n1
shapes, for example: paired, oblique, with holes or of
different sizes to one another (fig. 10.1-1).
Before performing the measuring run:
•
From the OPTIMA PARAMETERS screen select 1
next to the "Advanced Spoke Detection" item.
•
Perform the normal procedures for the run.
Note
: This function increases the time for the tota
measuring cycle by 5 seconds
9.8 OPTIMA PARAMETERS
(fig. 9.6-1)
F5
and
F6
have the same meaning of the screen relative
to the geodyna 6800 basic model.
a) Limit (threshold) for wheel first harmonic radial
runout. Preset value: 0.7 mm.
b) Limit (threshold) for wheel peak to peak radial
runout. Preset value: 1,5 mm.
c) Limit (threshold) for peak to peak radial/lateral
runout of rim only. Preset value: 1 mm.
d) Set the limit value for the Tread Depth TDI. The
scale is 0 to 10 mm
(0-0,400 ince)
. Set the value 0
or “0,00”
to disable the function; no icon appears
on screen.
Preset value: 1,7 mm
(0,068 ince)
.
e) The wheel data detection scan occurs always during
the first measuring run. This function allows the
exclusion of the activation of the laser scanner in
the following measuring runs, in order to optimise
the operating times whenever it is necessary to
carry out more than one measuring run for the same
wheel. By assigning value “0” the scan occurs
automatically and only at the first measuring run,
after fixing the wheel. By assigning value “1” the
scan occurs automatically at every wheel
measuring run (Preset value).
f)
Sets the rim runout measurement (if the value is 0
the measurement occurs only if the threshold is
exceeded; if the value is 1 the measurement
occurs always). Preset value: 0.
g) Runout measurement unit selection in mm or
inches. Preset value: mm.
h) Reset the preset default values.
i)
Saves the values set by the operator.
k) Automatically prints when the wheel is removed
(only if the printer is present and active). If the
value is “0” (preset) it doesn’t print, if the value is
“1” it prints.
m) Allows selection of RIM ONLY advanced diagnosis.
Select "1" = Enables RIM ONLY advanced diagnosis
and opens the screen shown in fig. 9.6-2.
Summary of Contents for geodyna optima
Page 1: ...geodyna optima Additional instructions Wheel balancer ...
Page 2: ......
Page 55: ...53 geodyna optima Operator s Manual Manuel d Utilisation Note Note page La página de la nota ...
Page 56: ...54 Electrical diagram ...
Page 57: ...55 Electrical diagram ...
Page 58: ...56 Electrical diagram ...
Page 59: ...57 Electrical diagram ...
Page 61: ...Note page ...