17 of 44
NOTE:
AS
ROD
EXTENDS,
OIL
FROM
CYLINDER
RETURNS
TO
POWER
PACK.
RELEASE
HANDLE
ON
POWER
PACK
NEEDS
TO
BE
HELD
DOWN
(OPEN)
TO
ALLOW
OIL
TO
RETURN
TO
POWER
PACK.
Continue
to
extend
the
rod
until
the
non
‐
threaded
end
of
the
cables
are
reached.
Remove
the
clamp
from
the
cable
flange.
Install
the
cables
as
shown
in
Figure
4,
Cable
and
Routing
Diagram.
Reinstall
the
clamp
to
the
cable
flange.
HYDRAULIC
AND
AIR
KITS
INSTALLATIONS
Locate
the
supply
lines:
1/4”
and
3/8”
polytube,
3/8”
flexible
hydraulic
line,
and
the
black
plastic
piping.
Install
the
black
plastic
piping
to
the
steel
pipe
welded
to
the
underside
of
the
front
left
side
crossmember
assembly.
7.8
AIR
INSTALLATIONS
Attach
the
air
valve
assembly
using
two
(2)
#8
‐
32
UNC
1”lg.
Phil.
HD.
screws
to
the
two
(2)
#8
‐
32
UNC
hex
nuts
on
the
outside
face
of
the
left
front
post.
NOTE:
MOST
OF
THE
1/4”
AND
3/8”
POLYTUBE
CONNECTIONS
HAVE
BEEN
MADE
IN
THE
CROSSMEMBERS
ASSEMBLIES
AND
LEFT
DECK.
ONLY
FINAL
CONNECTIONS
ARE
REQUIRED
TO
BE
MADE.
THE
1/4”
POLYTUBE
WILL
BE
USED
FOR
THE
AIR
CYLINDER
LOCKS
AND
THE
3/8”
POLYTUBE
WILL
BE
USED
FOR
THE
AIR
OUTLETS
TO
THE
JACKING
BEAMS.
CAUTION:
DO
NOT
OVER
TIGHTEN
CONNECTORS.
Connect
all
of
the
1/4”
polytubes,
which
have
been
previously
installed,
coming
out
of
the
black
plastic
piping
at
the
left
front
crossmember
assembly,
to
the
cross
and
tee
pushlock
fittings
at
the
front
and
rear
of
the
left
deck.
See
Hydraulic
&
Air
diagram
(Page
27).
Connect
the
opposite
end
of
the
1/4”
polytube,
coming
out
of
the
black
plastic
piping,
to
the
air
valve
on
the
outside
face
of
the
left
front
post.
Connect
the
3/8”
polytube,
coming
out
of
the
black
plastic
piping
at
the
left
front
cross
‐
member
assembly,
to
the
3/8”
polytube
fitting
at
the
front
inside
under
the
left
deck.
Connect
the
opposite
end
of
the
3/8”
polytube,
coming
out
of
the
black
plastic
piping,
to
the
air
valve
outlet
on
the
outside
face
of
the
left
post.
NOTE:
FOR
THOSE
UNITS
EQUIPPED
WITH
JACKING
BEAMS,
THIS
WOULD
BE
THE
TIME
TO
INSTALL
THEM.
CONSULT
THE
JACKING
BEAM
INSTRUCTIONS
MANUAL
FOUND
IN
EACH
JACK
BEAM
BOX.
‐
IF
JACK
BEAMS
ARE
INSTALLED,
PLUG
THE
ONE
REMAINING
OUTLET
AT
THE
FRONT
AND
REAR
OF
THE
LIFT.
‐
IF
JACK
BEAMS
ARE
NOT
INSTALLED,
USE
PLUGS
AND/OR
COUPLERS
TO
PLUG
AIR
OUTLETS.
Summary of Contents for FPA12144
Page 8: ...8 of 44 6 0 GENERAL LIFT SPECIFICATIONS Figure 1 ...
Page 12: ...12 of 44 7 3 SHEAVE INSTALLATION Figure 5 ...
Page 34: ...34 of 44 9 0 LIFT ASSEMBLY ...
Page 37: ...10 0 HYDRAULIC AND A AIR KITS AS 37 of 44 SSEMBLY ...
Page 39: ...11 0 CABLE RO OUTING DIAGRAM 39 of 44 ...
Page 42: ...13 0 POWER P PACK 6 1 1936 AB 1 42 of 44 1400 208 2 230V 1PH 60HZ ...