Operation 

 

2.1. 

Switch on the unit by means of the pull switch "power" on the rear panel of the 

unit.  

 

For more information on the pull switch, see also chapter "Meter counter". 

 

2.2. 

Tachometer / meter counter 

 

Switch located below the LCD set to:  

 

Σ

 m 

 

Length of marked line will be displayed.* 

 

km/h   

Travelling speed will be displayed. 

 

 

By switching over to 

Σ

 m, the accumulated counting for the line 

length will be shown on the display.  

                        

REMARK:

 

Whenever the magnetic valves are in operation (i.e. when a gun is activated), 

never remove the gun connector from the unit. The memory contents for the 

meter counter could be falsyfied or be completely lost. The figure 100 may 

appear on the display.  

 

By switching the unit on and off, you can make it operable and set the meter 

counter back to zero.  

                       

  Or: 

 

Set the "Start-Stop" switch to "Stop" and then back to "Start", whereby the meter 

counter is not set back to zero.  

Summary of Contents for 97 01 930

Page 1: ......

Page 2: ...results in the mentioned effects 1 5 Standstill and moving the machine to and for inside gaps Inside gaps between interrupted lines the electronic system has a so called direction detector The impulse...

Page 3: ...nd length of the line at a very low factor for example 10 cm Switch on the control unit Set the Semi Man Auto switch to Auto Drive off and set Start Stop switch to Start Drive slowly through a distanc...

Page 4: ...y switching over to m the accumulated counting for the line length will be shown on the display REMARK Whenever the magnetic valves are in operation i e when a gun is activated never remove the gun co...

Page 5: ...line at the selector switch IMPORTANT Cycle must be greater than length of line Due to various pneumatic and mechanical delays the actual line length really marked on the road deviates from the presel...

Page 6: ...mmed line this line is extended as a continuous line If the switch is operated inside a gap the continuous line does not begin until the gap is completed by the programme After returning to continuous...

Page 7: ...effect Set Semi Man Auto switch to Man Set Start switch to Start Operate remote control as long as line marking is required 2 10 Continuous line a fixed length 1 Possibility For lines less than 100 m...

Page 8: ...y simply adding the requried line length Set switch Start Stop to Start Drive off and activate the required line length with the remote control 3 Possibility In case the continuous line shall start im...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Reviews: