2.3
Total meter count
2.3.1 Adjust switch for
Σ
m - km/h to
Σ
m.
Then operate switch TOTAL COUNT left. The display shows the total marked line
length in meter since the last cancellation. The metering runs until 9999 m and
then begins again with 0. By switching off the apparatus the accumulated count
will not be cancelled.
2.3.2 Cancellation of the total meter count
Switch off the apparatus (pull-button at the back). Operate switch TOTAL COUNT
right and hold the switch and at the same time switch on again the apparatus.
Release the switch TOTAL COUNT. Counter is cancelled.
2.4
Setting programm:
Set the cycle (distance from beginning of line to next beginning of line) at the
selector switch
Set the length of line at the selector switch
IMPORTANT:
Cycle must be greater than length of line.
Due to various pneumatic and mechanical delays, the actual line length really
marked on the road deviates from the preselected length. For example the
deviation depends on the travelling speed and the control air pressure.
For this reason, after beginning a marking operation, the length of the line
actually marked on the road surface must be measured and must be adjusted at
the control unit accordingly. After changes in speed, air pressure etc. it is
recommendable to re-check and, if necessary, re-adjust the setting.
Adjusting the line length automatically alters the length of the gap contrary, as the
gap length automatically results of the length of the cycle minus the line length.
The length of the cycle remains constant, even if travelling speed,
control air pressure etc. vary.
This practical system, only requires observation and adjustment of line length.