5.0 Troubleshooting (Messages)
5.1 Error messages
Fault
Camera does not work, no IR-LEDs active, no LED of the board is shining.
Possible
Reason
Soldering pin on camera contross board broken(see mark left)
Fixing
Replace the board with the one with SMD capacitors. Exchange is necessary only if there
is a really fault. Function of both boards is the same.
Fault
Camera calibration was interrupted with unplausible values.
Possible
Reason
Calibration was not successful but was stored anyhow. Values of the car differ with 1
degree or more.
Fixing
Check the calibration bar if it is assembled correct. (Compare with sketch in the box)
Repeat calibration..
Fault
Camber values are always wrong on the same tyre position. Machine is calibrated but
values for camber are always shown with the same offset
Possible.
reason
Calibration can not be done better.
Fixing
It can happen that the values for camber must be corrected. This has nothing to do with
calibration, it can happen that there must be a camber correction after a successful
calibration.
We have the possibility to make pre corrections for the camber values.
These are experienced data and can be done if you have more aligners to compare
values. One unit is 1/100 of a degree. That means if you add -15 on the BL (back left)
camber all values are shifted at -15 1/100 degrees
Usually this "shifting" will be done in the factory right after calibration. They have tools to
measure and check calibration.
The values for camber can be changed in the CONFIG.INI that is placed in D:/SSENCE.
FL_Camber= 0
FR_Camber= 0
BL_Camber= 0
BR_Camber= 0