User Guide | Arcadia® Central Station
Example connection with a splitter
Note:
The splitter connections are switched between RJ45 and Fiber routing using DIP switches
inside the splitter.
For more examples of connection options and how to set the DIP switches, see the FreeSpeak
II Splitter Quick Start Guide available from the
FreeSpeak II Knowledge Center.
6.2.1
Cable Distances - E1 Connections
Arcadia Central Station to TCVR/splitter
TCVR directly connected to and powered by
the Arcadia Central Station
l
328 ft (100 m) using shielded 24 AWG
Cat 5/6e cable
l
164 ft (50 m) using shielded 26 AWG
Cat 5/6e cable
TCVR directly connected to the Arcadia
Central Station with local/direct power at
TCVR
l
2625 ft (800 m) using shielded 24 AWG
Cat 5/6e cable
l
1312 ft (400 m) using shielded 26 AWG
Cat 5/6e cable
Arcadia Central Station to splitter (splitter is
powered)
l
2625 ft (800 m) using shielded 24 AWG
Cat 5/6e cable
l
1312 ft (400 m) using shielded 26 AWG
Cat 5/6e cable
Page 97
Summary of Contents for Clear-Com ARCADIA Series
Page 12: ...User Guide Arcadia Central Station 1 2 Connections Page 12 ...
Page 52: ...User Guide Arcadia Central Station Page 52 ...
Page 71: ...User Guide Arcadia Central Station Page 71 ...
Page 83: ...User Guide Arcadia Central Station Page 83 ...
Page 99: ...User Guide Arcadia Central Station Page 99 ...
Page 108: ...User Guide Arcadia Central Station Unregister Page 108 ...
Page 119: ...User Guide Arcadia Central Station Page 119 ...
Page 137: ...User Guide Arcadia Central Station 6 Select the left hand option Page 137 ...
Page 144: ...User Guide Arcadia Central Station Page 144 ...
Page 146: ...User Guide Arcadia Central Station 14 1 GPIO pinouts GPIO 1 Relay 1 2 Page 146 ...