User Guide | Arcadia® Central Station
10.2
Port Function
Check this function whenever you are connecting 4-wire devices (not GPIO DB-9M connectors)
to your Arcadia Central Station. Default =
4-wire-X
.
10.2.1
About Port Function
Clear-Com products are designed so central audio routing devices (base stations and matrices)
can connect directly to other Arcadia Central Stations using a straight-through CAT 5/6 cable.
The pin assignments (inputs and outputs) on these devices are complementary. Previously, a
crossover cable was necessary when connecting bases to other bases (RJ45 connector). It is
no longer necessary to use a crossover cable as there is now a
Port Function
toggle which
changes pinouts as required. To set this function navigate in the CCM to
Hardware >
Rescources > Physical Ports
and select the required 4-wire port.
10.2.2
Port Function Pinouts
Pin No
4-wire
4-wire-X (default)
1
Data in +
Data out +
2
Data in -
Data out -
3
Audio in +
Audio out +
4
Audio out +
Audio in +
5
Audio out -
Audio in -
6
Audio in -
Audio out -
7
Data out +
Data in +
Page 126
Summary of Contents for Clear-Com ARCADIA Series
Page 12: ...User Guide Arcadia Central Station 1 2 Connections Page 12 ...
Page 52: ...User Guide Arcadia Central Station Page 52 ...
Page 71: ...User Guide Arcadia Central Station Page 71 ...
Page 83: ...User Guide Arcadia Central Station Page 83 ...
Page 99: ...User Guide Arcadia Central Station Page 99 ...
Page 108: ...User Guide Arcadia Central Station Unregister Page 108 ...
Page 119: ...User Guide Arcadia Central Station Page 119 ...
Page 137: ...User Guide Arcadia Central Station 6 Select the left hand option Page 137 ...
Page 144: ...User Guide Arcadia Central Station Page 144 ...
Page 146: ...User Guide Arcadia Central Station 14 1 GPIO pinouts GPIO 1 Relay 1 2 Page 146 ...