Assembly Instruction
Introduction
Torque Motor
TM-Komponenten-04-0-EN-2108-MA
Page 12 of 84
Table 1.3: Operation environment conditions Class 3K3
Environmental parameter
Unit
Value
Air temperature
(
℃
)
+5 ~ +40
Relative humidity
(%)
5 ~ 85
Absolute humidity
(g/m
3
)
1 ~ 25
Rate of change of temperature
1)
(
℃
/min)
0,5
Air pressure
2)
(kPa)
78,4 ~ 106
Solar radiation
(w/m
2
)
700
Movement of surrounding air
3)
(m/s)
1
Condensation
-
Not allowed
Formation of ice
-
Not allowed
1)
Averaged over a period of time of 5 min.
2)
Conditions in mines are not considered. Severity value is different from Class 3k3. (up to 78,4 kPa) (altitudes up to
2000 m).
3)
Uncontrollable air flow may affect cooling systems based on natural convection.
Mechanically active substances
Class 3S1
Mechanical conditions
Class 3M3
1.3.10
Maintenance and storage precautions
1
Do not store the product in an inflammable environment or with chemical agents.
2
Store the product in a place without humidity, dust, harmful gases or liquids.
3
Install the product in location with less vibration.
4
The way to clean the product: wipe with alcohol (70
%
)
5
The way to discard the damaged product: recycle it according to local laws and regulations.
6
Storage conditions must comply with EN 60721-3-1(Refer to Table 1.4 on the next page)
7
Motor can be stored for up to two years indoor with the following conditions:
nicht verwenden
Dry
nicht verwenden
Dust-free
nicht verwenden
No vibration
nicht verwenden
Good ventilation
nicht verwenden
Resistance to extreme weather
nicht verwenden
Indoor air does not contain corrosive gas
nicht verwenden
Prevent motor vibration and moisture
8
If no dry storage environment is available, the following measures need to be taken:
nicht verwenden
Wrap the motor with moisture-absorbing material, and then seal the motor.
nicht verwenden
Put desiccant in the sealed package; the desiccant needs to be checked and replaced if
necessary.
nicht verwenden
Check the motor regularly.
9
After long-term storage and removal of the motor, the insulation resistance value may be reduced due to
moisture. Before installing the machine, confirm the insulation resistance state of the motor. Use an
inspection instrument that meets EN61557. The test must reach 100
M
Ω
after 60 seconds at 1000
V
DC
. If
it does not meet the specifications, the motor may be damp. If it is used directly, it may cause insulation
damage. You can dehumidify the motor by yourself. The steps are as follows or please contact HIWIN: