output and display the error code shown on the
right. (The inverter will trip according to the
settings of "p45" and "P048".)
E61
Option error (duplicated
MACID)
If two or more devices having the same MAC ID
are detected in the same network, the inverter
will display the error code shown on the right.
E62
Option error (External trip)
If the Force Fault/Trip bit of Attribute 17 in the
Instance 1 of the Control Supervisory object is
set to "1", the inverter will shut off its output and
display the error code shown on the right.
E63
to
E68
Option error
The inverter detects errors in the option board
mounted in the optional slot. For details, refer to
the instruction manual for the mounted option
board.
E69
Option error (inverter
communication error)
If timeout occurs during the communication
between the inverter and DeviceNet option
board, the inverter will shut off its output and
display the error code shown on the right.
E80
Encoder disconnection
If the encoder wiring is disconnected, an encoder
connection error is detected, the encoder fails, or
an encoder that does not support line driver
output is used, the inverter will shut off its output
and display the error code shown on the right.
E81
Excessive speed
If the motor speed rises to "maximum frequency
(A004) x over-speed error detection level (P026)"
or more, the inverter will shut off its output and
display the error code shown on the right.
E83
Positioning range error
If current position exceeds the position range
(P072-P073), the inverter will shut off its output
and display the error code.
Summary of Contents for WJ-0001S
Page 2: ...Hitachi Solar Water Pump Inverter System KHKSCO GROUP ...
Page 16: ...Ii Single phase 200V 0 1 to 0 4kW Three phase 200V 0 1 to 0 75kW ...
Page 17: ...Ii ...
Page 18: ...Ii ...
Page 19: ...Solar Water System 4 Wiring details ...
Page 27: ...Operating Principle 5 And Hardware ...
Page 30: ...System Start up 6 ...
Page 42: ...Network Communication 7 ...