I
i
SJ700
D
series Inverter parameter setting for solar water pump inverter
After giving power to inverter, It show 0000 value of d001 parameter (output motor
Hz)
Check A017 = 0
2
For enabling MPPT algorithm, 00 means stop, 0
2
means for
terminal enabling.
First to set motor data inside of inverter like KW, Hz, RPM, Current, Votlage
A003 = Hz of motor
H003 = KW of motor
H004 = Pole of motor which come from RPM of motor.
A002 = 01 Terminal Run command
F002 = 100
Sec , Acceleration Time
F003 =
1
Sec , Deceleration time
A020 = Put Total Vmp of connect PV cells,
C001 = 56, Terminal 1 as Forward Run command
C006 = 18, Terminal 6 as Reset inverter
P101 = 3 min,
Auto restart delay time after inverter get any alarm, Change as per requirements
P1
30
= 3000,
Water level sensitivity,
For 60Hz Pump Make :
A017 = 00
P111 = 6000
Note : Make B037 = 00
A061 = 60
A003 = 60
A017 = 0
2
Summary of Contents for WJ-0001S