14
15
In
tro
duc
tion
SYSTEM SELECT Switch
Settings
OFF
ON
6
1
2
3
4
5
7
8
9
10
Switch 1 (Serial
communication baud rate
switch)
OFF* : 9,600 bps
ON : 38,400 bps
Switch 2 (IR OUT switch)
Allows the IR reception signal
from the remote control to be
output from the RS232C IN
terminal.
OFF* : Disables output
ON : Enables output
Switch 3 (RS-232C/RS-422
switch)
OFF* : Comm via RS-232C
ON : Comm via RS-422
Switch 4 (Video OUT Sync
switch)
[VZ-HD3600/3700/3780A]
Switches the Sync signal on/off
for analog video signal output.
Set this to add a Sync signal,
especially when not connected to
Analog Horizontal Sync/Analog
Vertical Sync.
OFF : Does not add Sync
ON* : Adds Sync
Switch 4 (Not used)
[VZ-HD3650A]
Always set to ON*.
Switch 5 (Not used)
Always set to OFF*.
Switch 6 (Not used)
Always set to OFF*.
– Switches 7-9 (remote
code switch)
Allows you to select the remote
control code (RC.1 to RC.3) to
receive in cases such as when
operating multiple cameras with
the same remote, or to avoid
interference from another remote
control for a nearby camera. To
prevent remote control operation
(RC OFF), set to anything other
than RC.1-RC.3.
7
OFF
ON
OFF
ON
OFF
ON
RC.1*
RC.2
RC.3
RC OFF
OTHERS
8 9
Switch 10 (Not used)
Always set to OFF*.
*
This is the factory default setting.
Summary of Contents for VZ-HD3600A
Page 61: ...61 Appendix Dimensional Drawing VZ HD3600A 4 M3 1 4 20UNC Ø5 Top Front Base Unit mm Side ...
Page 62: ...62 Appendix Dimensional Drawing VZ HD3650A 4 M3 1 4 20UNC Ø5 Top Front Base Unit mm Side ...
Page 63: ...63 Appendix Dimensional Drawing VZ HD3700A 4 M3 1 4 20UNC Ø5 Top Front Base Unit mm Side ...
Page 71: ...71 ...
Page 72: ...QR85781 Hitachi Industry Control Solutions Ltd 2015 Printed in Japan I ...