![Hitachi VSP F1500 User Manual Download Page 47](http://html.mh-extra.com/html/hitachi/vsp-f1500/vsp-f1500_user-manual_145977047.webp)
HTI volume
Access attribute to be assigned
Pair status
Volume
Read/Write
Read Only
Protect
S-VOL Disable
PSUE
P-VOL
Yes
Yes
S-VOL
Yes
No
Legend:
Yes: You can perform the setting
No: You cannot perform the setting.
Sharing Thin Image volumes with Hitachi Volume Migration
You cannot do the following:
• Perform Thin Image tasks on volumes reserved for Volume Migration
without regard to the migration plan status.
• Use Thin Image pair volumes or pool-VOLs as volumes reserved for
Volume Migration V2.
For more information about the migration plan status and Volume Migration
tasks, see the
Hitachi Volume Migration User Guide
.
Sharing Thin Image volumes with ShadowImage
You can share Thin Image (HTI) P-VOLs with ShadowImage (SI) P-VOL and
S-VOLs.
Available Thin Image tasks
The following table lists the Thin Image tasks you can perform when sharing
a Thin Image P-VOL with a ShadowImage P-VOL.
HTI task
SI pair status
COPY(P
D)/
COPY
PAI
R
COPY(S
P)/
COPY
PSUS(S
P)/
PSUS
PSU
S
COPY(R
S)/
COPY
COPY(R
S-R)/
RCPY
PSU
E
Create pair
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Store snapshot data
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Restore pair
No
No
No
No
Yes
No
No
Yes
Delete snapshot
data
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Release pair
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Legend:
Yes: You can perform the task.
No: You cannot perform the task (the command is rejected).
Overview of Thin Image
47