3. Operation Method
A11766820A
11
No.
Icon
Description
30
Quick
The operation is in quick mode.
31
Other remote are in ** setting
When the operation mode set from the remote controller and the operation
mode of the outdoor unit is different, the indicator blinks.
Fan Speed Louver
Menu
Cool
Cool
Indv.
26
.
5
Temp
26
.
5
Conference Room
Other remote are in Heat setting
Indicator blinks
When "Cool" is set from the remote controller and when the operation mode of
the outdoor unit is "Heat".
32
Emergency Heating →
Alarm Code: **
Emergency Heating Control is in progress.
** indicates the alarm code.
33
Auto Clean Unit
Mechanic error
Check the unit
Indicates an error related to the automatic filter cleaning unit.
34
Cleaning Filter
The filter is being automatically cleaned.
35
Check
Indicates an abnormality in the heat storage unit.
36
Preheating
The compressor cannot be operated because it is preheating.
37
HOT-START
Preparing for heating operation.
38
Defrost
During the defrosting operation, the defrosting light turns on and the indoor fan
stops.
When the operation is stopped during the defrosting operation, the operation
light or the run indicator goes out, but the operation continues and stops after
the defrosting is completed.
39
Heat Storage
It cannot be operated due to the heat storage operation time.
40
Dust collection **-**
It is time to collect dust in the dust box of the automatic filter cleaning unit.
**-** indicates the unit to be collected.
41
Central control
Displayed when using the central controller. Remote controller operation is
restricted.
42
Time to OFF(hour)
The remaining time of the off timer when the hotel mode is displayed.
43
Priority
Displayed on the main remote controller only in the operation mode or when
there is a setting priority for the operation mode and the set temperature.
At this time, the operation limit lights up on the sub remote controller, and the
operation mode and temperature setting change on the sub remote controller
are restricted.
44
Restrict
Displayed on the sub remote controller only when the operation mode or the
operation mode and set temperature setting priority is given.
(*1)
:
It depends on the settings of the remote controller.
(*2)
:
The default setting is cooling: set tempe4°F (+2.5°C), heating: set temperature -4°F
(
-2.5°C).
If you want to change the correction value for this setback operation, please contact the distributor for
more detailed information.