6 MAINTENANCE
6-9
Table 6-3 CPU Module Error Indications and Remedies (2)
No.
CPU module
indication
(S10mini)
Error code
(S10V)
Error description
Action
9 CPL
▲
TRM
0x00E0
Link line error:
A reception error occurred
successively or intermittently in G-
register area transfer.
• Check that the link cable extension
length is within the specified limit.
For the specified limit, see
“1.2 Specifications.”
• Check that the link cable and crimp
terminals are not broken or partly
broken.
• Check for improper terminating
resistor setup. For the setup
procedure, see “2.1 Names and
Functions of Each Part.”
10 CPL
▲
△.
□
0x0080
System program operating normally:
The CPU link module is operating
normally.
A normal operation is indicated.
No error is encountered.
11
No number
(between 1 and
10) appears.
None
(None):
The CPU link module is not normally
started due, for instance, to damaged
data in the ROM.
• Hold the CPU or LPU RESET
switch in the ON position for a
period of longer than one second
and then release it.
• If the indication does not go off,
replace the CPU link module
because it is defective.
• The value in the
△
mark position indicates the internal program version number. The value in
the
□
mark position represents the leftmost digit of the revision number.
• Either the
▲
mark or
■
mark appears to indicate whether the main module or sub-module is
affected. (When the S10V is used, the tool system gives this type of indication.)
MAIN/SUB selector switch
▲
■
“0” (MAIN)
M
0
“1” (SUB)
S
1
Summary of Contents for LQE550
Page 1: ......
Page 2: ......
Page 17: ...This Page Intentionally Left Blank ...
Page 19: ...This Page Intentionally Left Blank ...
Page 28: ...1 SPECIFICATIONS ...
Page 34: ...2 NAMES AND FUNCTIONS OF EACH PART ...
Page 38: ...3 MOUNTING AND WIRING ...
Page 46: ...4 OPERATION ...
Page 75: ...4 OPERATION 4 30 Figure 4 33 An Example of a CPU Link Parameters Output in CSV Format ...
Page 79: ...This Page Intentionally Left Blank ...
Page 80: ...5 PROGRAMMING ...
Page 88: ...6 MAINTENANCE ...