1
2
1
SWITCH DISPLAY
Discharge air pressure display
To various setting status display
显示转换
重新设定
Shutdown history of
DCBL controller
Shutdown history of
fan inverter
ⓐ
Increments by 1
each time pressed
Decrements by 1
each time pressed
Returns to
discharge
air pressure
display
Press 14 times.
①
Press the
SELECT
switch 14 times. “E6” and “E7” are
shutdown histories of the DCBL controller. 5 of “E5.” indi-
cates the oldest display of the digital monitor.
②
Press the
RESET
button. The screen returns to the usual
digital monitor display.
1
.
If the shutdown code “XX” is “
” it means there is
no shutdown history. When other than shutdown
history displayed without performing shutdown
reset, it returns to the newest shutdown history dis-
play 3 minutes later.
2
.
The shutdown histories of the DCBL controller and
the fan inverter are recorded for the latest shutdown
only. The shutdown code displays a dedicated code.
(
See shutdown code on this page.)
■
How to Check Cause of Shutdown When E0.13 (Controller Abnormality) and E0.57
(Fan Inverter Abnormality) and Shutdown History in DCBL Controller and Fan Inverter
IMPORTANT
26
5. TROUBLESHOOTING [SHUTDOWN/ALARM Indications on the Instrument Panel]
(a) DCBL Controller shutdown code
Code
Shutdown contents
Detection
Cause
E01
Overcurrent
protection
Software
Current protection circuit trip
Motor restraint
Sudden acceleration
E02
Hardware
E05
Overload protection
Electronic thermal trip
Motor overload
E07
Overvoltage protection
Over specifi ed converter voltage
High receiving voltage
E09
Voltage defi ciency protection Below specifi ed voltage
Receiving voltage drop, instantaneous power interruption
E10
CT error
Built-in CT abnormality
E20
Temperature trip
DCBL Controller fan abnormality
DCBL Controller fan rotation drop, DCBL controller fan wire break
E21
Temperature trip
Cooling fi n overheat
Cooling fi n, suction hole, cooler clogging, high ambient temperature
E22
Communication error 1 DCBL Controller internal communication abnormality Outside noise
E23
Gate array error
Gate array communication abnormality
E24
Phase-lacking connection protection Input phase-lacking connection
E30
IGBT error
Generation of instantaneous overcurrent
E33
Communication error 2 Communication abnormality between DCBL controller and control board Outside noise
E35
Motor overheat
Motor overheat
Cooling fi n, suction hole, cooler clogging, high ambient temperature
(b) Fan inverter shutdown code
Code
Shutdown contents
Detection
Cause
E01
※
Overcurrent
protection
Fixed speed
Current protection circuit trip
Motor restraint
Sudden acceleration
E02
※
Deceleration
E03
※
Acceleration
E04
※
Other
E05
Overcurrent protection
Electronic thermal trip
Motor overload, restart immediately after stopping
E07
※
Overvoltage protection
Over specifi ed converter voltage
High receiving voltage
E08
EEPROM error
Abnormal data in EEPROM
Outside noise, temperature rise
E09
※
Voltage defi ciency protection
Below specifi ed voltage
Low receiving voltage
E11
CPU error
Built-in CPU abnormality
E14
Short-circuit protection
Short-circuit when power turned on
Between output section and motor
E15
Receiving overvoltage
Over specifi ed voltage
Receiving voltage higher than specifi cation voltage
E21
Temperature trip
Temperature abnormality
Cooling fi n, suction hole, cooler clogging, high ambient temperature
E23
Gate array error
Gate array communication error
E60
Communication error
Communication abnormality between inverter and CPU printed curcuit board
Communication line break, outside noise
※
Retry operation target item