Item
Name
Min
Max
Description
3
•
Virtual
Storage
Director
(2.1GHz)
•
Virtual
Storage
Director
(2.3Ghz)
2 (1
pair)
8 (4
pairs)
A VSD may contain either an Intel Xeon 2.1GHz or 2.3GHz 8-core
microprocessor. The VSDs must be installed in pairs and the VSDs control the
front-end directors, back-end directors, PCI-Express interface, local memory,
and communication to the SVP. The VSDs are independent of the front-end
directors and back-end directors, and can be shared across them.
4
Cooling fan
(intake)
5
5
The five intake fans on the front of the controller pull air into the controller
and distribute it across the controller components.
5
Cache Path
Control
Adapter
(CPA)
1
4
The CPA uses the built in switch to connect the VSDs to the front-end
directors, back-end directors, and the cache backup memory. It distributes
data (data routing function) and sends hot-line signals to the VSD. The
shared memory is located on the first CPA cache board in each cluster in the
primary controller
Figure 4 Controller, rear view
Table 6 Controller components - rear
Item
Name
Min
Max
Description
1
Power
supply
2
4
200-240 VAC input. Provides power to the controller chassis in a
redundant configuration. Each power supply contains two
cooling fans to ensure constant cooling if one fan fails.
2
Service
Processor
(SVP)
1
2
A custom PC monitoring and controlling the storage system. It
contains the Device Manager - Storage Navigator software used
to configure and monitor the system. Connecting the SVP to a
service center enables the storage system to be remotely
monitored and maintained by the support team.
Introduction
31
Hitachi Virtual Storage Platform G1000, G1500, and Virtual Storage Platform F1500 Hardware Guide