Safety and environmental information
Caution:
Before operating or servicing the storage system, read about
Safety requirements on page 69
and the environmental information in
Regulatory compliance on page 183
.
Power control panel
The power control panel is located in the top left corner of the controller. It is
covered by a 2U-high bezel that can be removed separately from the 8U
bezel that covers the rest of the controller.
The following illustration shows the switches and indicators on the control
panel. The table following the figure explains the components and LED
meanings. All LEDs are shown ON to demonstrate the color of the LED.
Figure 32 Storage system control panel
Table 21 Storage system power controls and status indicators
Item
Description
1
REMOTE MAINTENANCE switch
•
Set to ENABLE to allow remote maintenance.
•
Set to DISABLE to prevent remote maintenance.
2
ENABLE switch Used to enable the PS ON/PS OFF switch. See
Power on procedures on page 110
.
3
POWER switch. Move up or down to turn system power on or off. See
Power on procedures on page 110
.
4
READY LED - indicates the operational status of the system
•
Off when the channel interface is not operational.
•
Green Indicates that input/output operation on the channel interface is enabled.
5
ALARM LED
•
Off when the system is off or when the system is on and operational without failures .
•
Red when the SVP detects a component failure or other failure condition in the system
108
Power on/off procedures
Hitachi Virtual Storage Platform G1000, G1500, and Virtual Storage Platform F1500 Hardware Guide