11. Installation configuration
TCGB0075 rev.0 - 11/2012
144
Solar combination (Installation example 7)
N O T E
Solar combination is not available when the HITACHI domestic hot water tank is integrated over the indoor unit.
Two space heating applications (High & Low water temperature) + Domestic Hot Water Tank + Solar combi Heating
complement (Boiler or Electric heater combination): Two space heating application with a Room Thermostat as an option
heated by Heat Pump and alternating boiler or supplemented by 3-stage electrical heater. Domestic Hot Water Tank is
heated by Heat Pump and also by free energy of the sun by means of a field supplied Solar panel and field supplied Solar
Kit. The LCD is integrated with the DHW Tank.
Item Description
1
Outdoor unit
2
Indoor unit
3
R134a compressor
4
Water pump
5
3-way valve
6
T-branch
7
Shut-off valves (field supplied)
8
Domestic hot water tank
9
Security valve
(DHWT-SWG-01 accessory)
10 DHWT heater
(integrated with DHWT)
Item Description
11 LCD controller
(integrated with DHWT)
12 Second temperature kit
(ATW-2KT-01 accessory)
13
Motorized valve (field supplied)
14 Aquastat
(ATW-AQT-01 accessory)
15
Boiler (field supplied)
16 Water check valve
(ATW-WCV-01 accessory)
17
Solar Kit (field supplied)
18 Solar pump & control
(field supplied)
Item Description
19
Solar panel (field supplied)
20 Hydraulic separator
(ATW-HSK-01 accessory)
A
2nd Water Temperature sensor
(ATW-WTS-02 accessory)
B
Secondary water pump
C
Mixing valve
D
Hydraulic separator
E
Shut-off valve
F
Universal water sensor (Two3)
(ATW-WTS-02Y accessory)
G
Water pump 3 (WP3)
(field supplied)
12
D
E
9
B
C
A
G
F
Boiler
Boiler
Signal
20
13
16
Domestic
Water
High Temperature (80ºC)
Low Temperature (35ºC)
1
7
4
6
5
3
2
DHW Tank
17
18
Solar Kit (field supplied)
15
17
7
16
19
11
10
8
14