10. Electrical wiring
TCGB0075 rev.0 - 11/2012
131
10
Recommended minimum sizes for field provided wires
N O T E
• Follow local codes and regulations when selecting field wires, circuit breakers and earth leakage breakers.
• Use the wires which are not lighter than the ordinary polychloroprene sheathed flexible cord (code designation
H05RN-F).
• (*1): The DHW tank heater is intended to be used in case of indoor and/or outdoor unit malfunction. If the DHW
tank heater is enabled during the indoor unit operation, CB and ELB could switch off. If it is desired to enable
the DHW tank heater operation during normal indoor unit operation, adjust the DSW4 pin 1 of the PCB1 to the
ON position and consider the protections as indicated in “Indoor unit + DHW tank heater combination” on the
table.
Outdoor unit
Model
Power supply
Max. Current
(A)
Power supply cables Transmiting cables
Actuator cables
EN60335-1
EN60335-1
EN60335-1
RAS-4HVRNME-AF
1~ 230V 50Hz
18.0
2 x 4.0 mm² + GND
2 x 0.75 mm
2
(*Shielded cable)
2 x 0.75 mm
2
+ GND
RAS-5HVRNME-AF
23.0
2 x 6.0 mm² + GND
RAS-6HVRNME-AF
23.0
2 x 6.0 mm² + GND
RAS-4HRNME-AF
3N~400V 50 Hz
7.0
4 x 2.5 mm² + GND
RAS-5HRNME-AF
11.0
4 x 4.0 mm² + GND
RAS-6HRNME-AF
13.0
4 x 4.0 mm² + GND
Indoor unit alone
Model
Power supply
Max. current
(A)
Power supply cables Transmiting cables
Actuator cables
EN60335-1
EN60335-1
EN60335-1
RWH-4.0FSVNFE
1~ 230V 50Hz
24.0
2 x 6.0mm
2
+ GND
2 x 0.75mm
2
(*Shielded cable)
2 x 0.75mm
2
+ GND
RWH-5.0FSVNFE
28.0
RWH-6.0FSVNFE
31.0
RWH-4.0FSNFE
3N~ 400V 50Hz
15.0
4 x 2.5mm
2
+ GND
RWH-5.0FSNFE
15.0
RWH-6.0FSNFE
15.0
Indoor unit with DHW tank
Model
Indoor Unit
Model
Operation mode
(*1)
Power
supply
Max.
current
(A)
Power
supply
cables
Transmiting
cables
Actuator
cables
EN60335-1 EN60335-1
EN60335-1
RWH-(4.0-6.0)FSVNFE
+
DHWS-(195/260)S-2.0H1E
RWH-4.0FSVNFE
Standard operation
(By default)
1~ 230V
50Hz
24.0
2 x 6.0mm
2
+ GND
2 x 0.75mm
2
(*Shielded
cable)
2 x 0.75mm
2
+ GND
RWH-5.0FSVNFE
28.0
RWH-6.0FSVNFE
31.0
RWH-4.0FSNFE
Indoor unit + DHW
tank heater combi-
nation
33.0
2 x
10.0mm
2
+
GND
RWH-5.0FSNFE
37.0
RWH-6.0FSNFE
40.0
RWH-(4.0-6.0)FSNFE
+
DHWS-(195/260)S-2.0H1E
RWH-4.0FSVNFE
Standard operation
(By default)
3N~ 400V
50Hz
15.0
4 x 2.5mm
2
+ GND
RWH-5.0FSVNFE
15.0
RWH-6.0FSVNFE
15.0
RWH-4.0FSNFE
Indoor unit + DHW
tank heater combi-
nation
25.0
4 x 4.0mm
2
+ GND
RWH-5.0FSNFE
25.0
RWH-6.0FSNFE
25.0