recommended polling time: ( 2) minutes.
SCT capabilities: (0x10bd) SCT Status supported.
SCT Feature Control
supported.
SCT Data Table
supported.
6.
Review the SMART Attributes Data section of the retrieved data to verify
that there are no “Current_Pending_Sector” or “Offline_Uncorrectable”
events on either drive.
In the sample output from the smartctl command below, the portion of
the information that indicates “Current_Pending_Sector” or
“Offline_Uncorrectable” events is underlined:
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH
TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 080 064 044 Pre-
fail Always - 102792136
3 Spin_Up_Time 0x0003 096 096 000 Pre-
fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020
Old_age Always - 13
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-
fail Always - 0
7 Seek_Error_Rate 0x000f 065 060 030 Pre-
fail Always - 3326385
9 Power_On_Hours 0x0032 100 100 000
Old_age Always - 156
10 Spin_Retry_Count 0x0013 100 100 097 Pre-
fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020
Old_age Always - 13
184 Unknown_Attribute 0x0032 100 100 099
Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000
Old_age Always - 0
188 Unknown_Attribute 0x0032 100 100 000
Old_age Always - 0
189 High_Fly_Writes 0x003a 100 100 000
Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 074 048 045
Old_age Always - 26 (Lifetime Min/Max 25/27)
191 G-Sense_Error_Rate 0x0032 100 100 000
Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000
Old_age Always - 12
193 Load_Cycle_Count 0x0032 100 100 000
Old_age Always - 13
194 Temperature_Celsius 0x0022 026 052 000
Old_age Always - 26 (0 20 0 0)
195 Hardware_ECC_Recovered 0x001a 116 100 000
Old_age Always - 102792136
197 Current_Pending_Sector 0x0012 100 100 000
Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000
Old_age Offline - 0
86
Hard disk replacement
Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference
Summary of Contents for 3080 G1
Page 6: ...6 Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 11: ...Thank you Preface 11 Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 12: ...12 Preface Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 18: ...18 About this manual Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 27: ...Mandatory regulations 27 Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 28: ...28 Mandatory regulations Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 104: ...104 Hard disk replacement Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 132: ...132 Server replacement procedures Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 137: ...Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...