Item
Description
1
PSU 1
2
PSU 2
Figure 14 PSU components
Item
Description
1
PSU fan
2
Power plug
3
Retaining latch
4
Handle
5
DC power LED
6
Malfunction or failure LED
7
AC power LED
Procedure
1.
Remove the power cord from the PSU.
2.
Move the retaining latch to the right (you may hear a slight click if the
PSU moves when the latch disengages).
3.
Using the handle on the PSU, pull the PSU out from the back of the
server until you can completely remove the PSU from the chassis.
4.
Insert the replacement PSU. The retention latch should click into position
all the way to the left when the PSU is fully inserted.
If the PSU that is not being replaced is receiving mains power when the
replacement PSU is fitted, the fan on the replacement PSU becomes
active.
5.
Connect the power cord to the back of the PSU.
The PSU should start as soon as the power connection is made. If the
PSU does not start immediately, make sure the mains power circuit is live
and that the other end of the power cable is connected to a live outlet.
68
Replacing server components
Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference
Summary of Contents for 3080 G1
Page 6: ...6 Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 11: ...Thank you Preface 11 Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 12: ...12 Preface Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 18: ...18 About this manual Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 27: ...Mandatory regulations 27 Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 28: ...28 Mandatory regulations Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 104: ...104 Hard disk replacement Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 132: ...132 Server replacement procedures Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...
Page 137: ...Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference ...