MAINTENANCE
7-47
Interval (hours) Check Points
Abnormalities
Remedies
Every 250
hours
Hose covers
Damage or leak (4)
Replace
Hose ends
Damage or leak (5)
Replace
Hose covers
Exposed reinforcement (6)
Replace
Hose covers
Crack or blister (7)
Replace
Hose
Bend (8), Collapse (9)
Replace
Hose ends
and Fittings
Deformation or corrosion
(10)
Replace
Lines
Interval (hours)
Check Points
Abnormalities
Remedies
Daily
Contact surfaces
of flange joints
Leak (11)
Replace
Bolts
Loose or leak (11)
Retighten or
replace O-ring
Welded surfaces
on flange joints
Leak (12)
Replace
Every 250
hours
Flange joint neck
Crack (13)
Replace
Welded surfaces
on flange joints
Crack (12)
Replace
Clamps
Missing or
deformation Loose
bolts
Replace or
retighten
Hose and Lines
Interval (hours)
Check Points
Abnormalities
Remedies
Daily Check
Flexible master
coupling
Leak (14)
Replace or
retighten
Oil Cooler
Interval (hours)
Check Points
Abnormalities
Remedies
Every 250
hours
Coupling
Leak (15)
Retighten or
replace
Oil Cooler
Leak (16)
Replace
9
10
7
6
12
13
12
13
11
M115-07-146
M115-07-147
M115-07-148
M115-07-149
M137-07-001
M137-07-007
16
15
MDCN-07-027
MDCN-07-028
ZX135US-5B
ZX225US-5B, 225USLC-5B
15
16
15
15
4
5
8
MDCD-07-044
14
Summary of Contents for 090001
Page 4: ......
Page 9: ...CONTENTS Bucket Teeth Transverse Type Pin Used Type 13 18 INDEX 14 1 ...
Page 10: ...CONTENTS MEMO ...
Page 14: ...MACHINE NUMBERS 4 MEMO ...
Page 64: ...MEMO SAFETY SIGNS S 50 ...
Page 198: ...OPERATOR S STATION 1 134 MEMO ...
Page 200: ...BREAK IN 2 2 MEMO ...
Page 212: ...OPERATING THE ENGINE 3 12 MEMO ...
Page 266: ...OPERATING THE MACHINE 5 46 MEMO ...
Page 398: ...MAINTENANCE 7 124 MEMO ...
Page 399: ...8 1 HYDRAULIC CIRCUIT AND ELECTRICAL CIRCUIT Hydraulic Circuit MDAA 08 001 ...
Page 402: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 2 MEMO ...
Page 404: ...STORAGE 10 2 MEMO ...