![Hirschmann MS30, Power MICE, MACH 4000, OCTOPUS User Manual Download Page 150](http://html1.mh-extra.com/html/hirschmann/ms30-power-mice-mach-4000-octopus/ms30-power-mice-mach-4000-octopus_user-manual_2138036150.webp)
Operation Diagnostics
146
9.6 TP cable diagnosis
Layer 2 Enhanced with Layer 2 Professional
Release 1.0 10/05
9.6 TP cable diagnosis
The TP cable diagnosis allows you to check the connected cables for short
circuits or interruptions.
Note:
While the check is being carried out, the data traffic at this port is
suspended.
The check takes a few seconds. After the check, the “Result” row contains
the result of the cable diagnosis. If the result of the check shows a cable er-
ror, then the “Distance” row contains the distance of the port from the cable
error.
Prerequisites for a proper cable diagnosis:
D
1000BASE-T port is connected via an 8 core cable with a 1000BASE-T
port or
D
10BASE-T/100BASE-TX port is connected with a 10BASE-T/100BASE-
TX port.
Result
Meaning
normal
The cable is okay.
open
The cable is interrupted.
short circuit There is a short circuit in the cable.
unknown
No cable check was carried out yet, or one is
being carried out at present..
Table 12: Meaning of the possible results
V
Select the
Diagnostics:Ports:TP cable diagnosis
. dialog.
V
Select a TP port at which you want to carry out the check.
V
Click on “Set” to start the check.
Summary of Contents for MS30, Power MICE, MACH 4000, OCTOPUS
Page 8: ...Contents 8 Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Page 10: ...About this Manual 10 Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Page 14: ...Introduction 14 Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Page 194: ...188 Index Layer 2 Enhanced with Layer 2 Professional Release 1 0 10 05...
Page 195: ......
Page 196: ......