Error code list
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: [email protected] · www.hirschmann.com
41
24 183 19 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
Error Code
Error
Cause
Elimination
value in measuring
channel "luffing jib
angle"
•
Electronic component in the
measuring channel defective.
•
Replace sensor unit
E21
Upper limit value in
measuring channel
"main boom length" has
been exceeded.
•
refer to E11
•
refer
to
E11
E22
Upper limit value in
measuring channel
"pressure piston side"
has been exceeded
•
refer to E12
•
refer
to
E12
E23
Upper limit value in
measuring channel
"pressure rod side" has
been exceeded.
•
refer to E12
•
refer
to
E12
E24
Upper limit value in
measuring channel
"force" has been
exceeded.
•
refer to E14
•
refer
to
E14
E25
Upper limit value in
measuring channel
"main boom angle" has
been exceeded.
•
refer to E15
•
refer
to
E15
E26
Upper limit value in
measuring channel
"angle 2" has been
exceeded.
•
refer to E16
•
refer
to
E16
E27
Upper limit value in
measuring channel
"length telescope I (+II)
has been exceeded.
•
refer to E17
•
refer
to
E17
Upper limit value in
measuring channel
"slewing angle 1" has
been exceeded
•
refer to E1A
•
refer
to
E1A
E2A
slew above allowed
range
•
1-cannel slew sensor max.
value DGA 11.5.8 <> 0
•
move to allowed slew range
E2B
Upper limit value in
measuring channel
"slewing angle 2" has
been exceeded
•
refer to E1A
•
refer
to
E1A
E2C
Upper limit value in
measuring channel
"luffing jib angle" has
been exceeded
•
Angle
potentiometer
defective
•
Electronic component in the
measuring channel defective.
•
Replace angle sensor
•
Replace sensor unit
E31
Error in the system
program
•
The system program file is
defective.
•
Flash-EPROM
defective
•
Upload valid system software
•
Replace central unit