Error code list
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: [email protected] · www.hirschmann.com
44
24 183 19 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
Error Code
Error
Cause
Elimination
EAD
No valid A2B switch
status
•
Sensor
wrong
function
•
CAN
bus
delay
•
Radio telegram delay module
(radio A2B)
•
Radio telegram ID is invalid
•
Replace A2B switch
•
Replace cable to the A2B
switch
•
Replace battery of radio module
(radio A2B)
•
Setup ID in DGA12.9
EDB
Datalogger setup error
•
Setup of the datalogger is
cleared (ser. crane data file or
battery buffered RAM)
•
transfer data and setup
datalogger again
EDC
Datalogger watchdog
activated
•
datalogger processing time limit
exceeded
•
Reset
system
•
Connect PC terminal and watch
error messages
EDD
Battery empty
•
Battery check detected a low
voltage of the battery
•
change battery, after this setup
of RTC
EDE
Record lost
•
Not possible to save data
because other task saves data
at the same time
•
Message disappears after a few
seconds
EDF
Flash block full
•
Not possible to save any more
data
•
Message disappears after a few
seconds
EFD
LMI Watchdog
extra time
•
a function needs more than 0.5
sec, e.g. Flash PROM write
•
Message disappears after a few
seconds