Integrated Control System 500
5
6.1.2.1.3.Alternate Program Switch
PROGRAM
(Programa)
A
B
Each of the 256 stage programs has another “shadow” program. This
separate program is provided to make the change between brooding
and full house operation. Position A is a program tailored for
brooding, whereas program B is for full house operation.
6.1.2.1.4.Target Temperature
TARGET TEMPERATURE
(Temperatura Optima)
INCREASE
DECREASE
(Disminuir)
(Aumentar)
The target temperature knob is used for the adjustment of target
temperature. This setting is very important, because all system
operations other than the timer are operated by the distance between
target temperature and actual temperature. At all times, the system
will try to maintain target temperature.
6.1.2.1.5.Timer Percentage
TIMER PERCENTAGE
(Reloj De Ventilacion Minima)
TIMER
INCREASE
DECREASE
(Disminuir)
(Aumentar)
This control allows the operator to specify the amount of time a stage
on the timer stays energized. For example:
10 Minute timer with Timer Percentage at 40%
The stage will be active for 40% of 10 min.--4 min.
The timer percentage control works in the same manner for a 5 minute
timer.
On this display, the word "Timer" will be backlit red if the stages on
the timer are active.
Summary of Contents for ICS-500
Page 13: ...Integrated Control System 500 11...
Page 14: ...Integrated Control System 500 12...
Page 15: ...Integrated Control System 500 13...
Page 18: ...Integrated Control System 500 16...
Page 23: ...Integrated Control System 500 21...
Page 24: ...Integrated Control System 500 22...
Page 25: ...Integrated Control System 500 23...
Page 31: ...Integrated Control System 500 29...