5.7.5 Other Settings
5.7.5.1 Uniformity Bandwidth
The Uniformity Bandwidth is a percentage that is used to determine the
permitted weight offset to consider a bird as a being uniform or not. For
example, if the uniformity bandwidth is set to 10%, all birds weighing more
or less than 10% from the average bird weight are considered as uniform
birds. This value can be adjusted from 3 to 50%.
Select the "
8. Installation
" menu from the main menu then press the
right-arrow key. Note that this menu is only accessible from the installer
mode.
Select the
"3. Other Settings"
menu
then press the right-arrow key. The
uniformity bandwidth flashes on the
display.
Use the adjustment buttons to set the
uniformity bandwidth to the desired
value.
5.7.5.2 Uniformity Error
The Uniformity Error is a percentage that is used to define the permitted
weight offset to consider a weight as a bird or not. For example, if the
uniformity error is set to 25%, all the weights that are higher or lower than
25% from the average bird weight are not be considered as being bird weights
and are not logged into the controller. The high and low uniformity error
weight range must be defined separately.
It is NOT suggested to change the initial value of this parameter!
By default, the Uniformity Error is set to +/- 25% from the
average bird weight.
8. Installation
3. Other Settings
8.3 Installation
Uniformity bandwidth
10%