Part n° 890-00487 rev.00
Evolution Bird Scale Controller
32
Main Menu
Bird Weigher Vx.x
8. Installation
8.1 Installation
# of scales
4
Min: 1 Max: 4
8. Installation
1. # of scale
5.7.2 Number of Scales
The controller can monitor up to 4 scales. The following procedure shows
how to select the number of scales that are connected to the main con-
troller (refer to section 5.6 to enable the scales afterwards).
Use the arrow keys to select the
"8. Installation"
menu then press
the right-arrow key. This menu is
only accessible from the installer
mode (sec. 5.7.1).
Press the right-arrow key once
again to select the
"1. # of Scales"
menu.
Use the adjustment buttons to set
the proper number scales. Adjust-
able from 1 to 4 scales.