![Hiniker 8605 Operator'S Manual Download Page 24](http://html.mh-extra.com/html/hiniker/8605/8605_operators-manual_2136895024.webp)
TITLE
22 Installation - Basic Unit
CONTROLLER MOUNTING
Select a convenient location to mount the 8605
controller.
This location should provide the operator with a
good view of the controller display and easy ac-
cess to all switches.
There are 7 cables connecting the controller to
the other parts of the system. They are listed in
the table. The controller location should allow
easy routing of these cables.
CABLE
CONNECTED TO
POWER
BATTERY OR CAB POWER
OUTLET
SERVO
SERVO VALVE
SPEED
SPEED SENSOR
FLOW
FLOWMETER
BOOM
BOOM VALVES
REMOTE RUN/HOLD REMOTE RUN HOLD SWITCH
I/O
EXTERNAL RATE INPUT OR
PRINTER
Install the “U” shaped mounting bracket as shown
in Figure 1, using the hardware supplied.
INSTALLATION - BASIC UNIT
DWG. NO. 3442A
Figure 1