STEP
DISPLAYED
ACTION YOU TAKE
7
VALVE RESPONSE 5
Set value for valve response in automatic 1 to 9.
Use numeric keys or the key.
Larger number = faster response.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
8
FLOW METER
CALIBRATE 72.0
This number must match the pulses per gallon number on the de-
cal on the flowmeter.(Do not use the pulse per pound number).
Use numeric keys to set value or
Press key to increase number.
Press key to decrease number.
IMPORTANT: Make sure you enter the pulses per gallon
calibration number.
17.0 PULSES/LB PULSES/Gal 72.0
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
9
DIST. CALIBRATION
FACTOR 2.00
Use numeric keys to set value or
Press key to increase calibration factor.
Press key to decrease calibration factor.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
If you have not performed the distance calibration procedures as outlined on page 16. You must do
so to determine what the distance calibration factor is. By performing the distance calibration on
page 16 the 8605 will automatically enter the distance calibration factor for step 9. If using a Hiniker
GPS Speed Sensor enter 2.00 as the Calibration number.
10
BOOM #1 WIDTH
240 INCHES
Enter width of applicator section #1 or total machine width if
only 1 section. (Use numeric keys to set valve or)
Press key to increase the width of applicator, in inches, for section #1.
Press key to decrease the width of applicator, in inches, for section #1.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
11
BOOM #2 WIDTH
240 INCHES
Enter width of applicator section #2 or 0 if total machine width
was entered in step #10. (Use numeric keys to set valve or)
Press key to increase the width of applicator, in inches, for section #2.
Press key to decrease the width of applicator, in inches, for section #2.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
12
INITIALIZING SERVO
VALVE
THE SYSTEM WILL AUTOMATICLY EXIT CALIBRATION
AND INITIALIZE THE SERVO VALVE TO THE MINIMUM
FLOW POSITION AND BEGIN OPERATION.
Calibration 21