CALIBRATION PROCEDURES - ANHYDROUS
AMMONIA
Read General Calibration page 16.
This calibration procedure is used to set up the
controller to be used with an applicator for apply-
ing Anhydrous Ammonia. Application rates are in
actual pounds of nitrogen applied.
CAUTION: If you and your operator(s)
are not intimately familiar with proper
handling procedures for Anhydrous
Ammonia, contact your supplier for informa-
tion, and read all safety precautions found in the
“HINIKER ANHYDROUS AMMONIA MONI-
TORING AND CONTROL SYSTEM MANUAL.”
Part number 360-000-246. Additional manu-
als may be obtained from your local dealer.
Refer to manual Part No. 360-000-246 Revi-
sion E or higher for Heat Exchangers man-
ufactured prior to 2007. These are painted
Gray.
or
Refer to manual Part No. 39300035 for Heat
exchangers manufactured in 2007 or after.
These are painted White Additional manuals
may be obtained from your local dealer.
20 Calibration
CALIBRATION PROCEDURES - ANHYDROUS AMMONIA
STEP
DISPLAYED
ACTION YOU TAKE
1
CALIBRATION MODE
Select Calibration Mode from the Main Menu.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
2
FIELD NUMBER
Use numeric keys to enter field number. (1-99) or
Press key to increase number.
Press key to decrease number.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
3
CHEMICAL NUMBER
Use numeric keys to enter chemical number. (1-16) or
Press key to increase chemical number.
Press key to decrease chemical number
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
4
APPLICATION:
Press , keys to make selection.
1. SPRAY
2. NH
3
Select 2. NH
3
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
5
APPLY RATE 1
100.0 LBS/ACRE
Use numeric keys to set value or
Press key to increase the gallon per acre for Rate 1.
Press key to decrease the gallon per acre for Rate 1.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
6
APPLY RATE 2
200.0 LBS/ACRE
Use numeric keys to set value or
Press key to increase the gallon per acre for Rate 2.
Press key to decrease the gallon per acre for Rate 2.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.