Calibration 19
STEP
DISPLAYED
ACTION YOU TAKE
14
BOOM #4 WIDTH
0 INCHES
Use numeric keys to set value or
Press key to increase the total width in inches for boom #4.
Press key to decrease the total width in inches for boom #4.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
15
BOOM #5 WIDTH
0 INCHES
Use numeric keys to set value or
Press key to increase the total width in inches for boom #5.
Press key to decrease the total width in inches for boom #5.
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
16
INITIALIZING SERVO
VALVE
THE SYSTEM WILL AUTOMATICLY EXIT CALIBRATION
AND INITIALIZE THE SERVO VALVE TO THE MINIMUM
FLOW POSITION AND BEGIN OPERATION.
MINIMUM FLOW RATE
The MINIMUM FLOW RATE procedure can be
entered at any time by pressing the MENU key
and selecting 4. MINIMUM FLOW RATE.
The MINIMUM FLOW RATE is a setting that will
cause the 8605 to stop reducing the flow below
this minimum limit as you slow down. This pre-
vents a poor spray pattern from your nozzles by
keeping the pressure at an acceptable level.
NOTE:
the MINIMUM FLOW RATE is only avail-
able in the SPRAY MODE. It is not available for
NH3 applications.
STEP
DISPLAYED
ACTION YOU TAKE
1
MIN FLOW SETUP
MIN FLOW IS OFF
Press to turn the minimum flow feature on
Press to turn the minimum flow feature off
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
2
MIN FLOW SETUP
SET MIN FLOW? N
Press to change to yes “Y”
Press to change to no “N”
PRESS ENTER KEY TO ADVANCE TO NEXT STEP.
3
ADJUST PRESSURE
THEN PRESS ENTER
Pump and booms must be on. Use keys to adjust for
minimum pressure while still maintaining a good spray
pattern.
PRESS ENTER TO SET THE LIMIT AND EXIT