background image

LIGHTING TOWERS  |  

PAG. 2

INDEX

 3

  1. Introduction

 4

  2. Safety regulations

 7

  3. Lighting tower: composition and location of its components

 9

  4. Technical information

10

  5. Start up

14

  6. Operations to carry out after use

15

  7. Maintenance

15

  8. Failures

16

  9. Guarantee conditions

RAMIRENT

Summary of Contents for KT12000

Page 1: ...INSTALLATION USE AND MAINTENANCE MANUAL LIGHTING TOWERS APOLO KIT TOWER KT8000 KT12000 R A M I R E N T...

Page 2: ...ion 4 2 Safety regulations 7 3 Lighting tower composition and location of its components 9 4 Technical information 10 5 Start up 14 6 Operations to carry out after use 15 7 Maintenance 15 8 Failures 1...

Page 3: ...ions HIMOINSA advises that the validity of the information in this handbook refers to the date that it was issued as several aspects such as the technological developments new regulations or updates a...

Page 4: ...er wearing loose clothes or objects that may be attracted by the airflow or by the mobile parts of the engine lt is forbidden to dismount or disable any safety device lt is forbidden to lean on the Li...

Page 5: ...ssible in order to avoid flare risks check that there is a grounds installation and that has been made according to Regulations Place a sign NO MANOEUVRING in all the sectioning organs that insulate t...

Page 6: ...ative one Negative pole to the engine block Check the cyclical direction of the phases is according to the mains lndividualize the position of the emergency stop button pushers the quick fuel intercep...

Page 7: ...d anodized with a 15 microns layer 3 2 2 SUPPORT FOR SIX PROJECTORS KT8000 Made of quartz iodine with 1 500W power and a flow of 33 100 lumens each The tower has a lighting capacity of 198 000 lumens...

Page 8: ...rigid shaft articulated nozzle optional 1 hooking on eye 2 hiding jockey wheel 3 4 extensible legs protected with nylon in all their surface 4 on the chassis it has 4 lifting eyes clearly indicated 5...

Page 9: ...Standard Standard Lamps n 6 x 1500 W 6 x 2000 W Lamps type Quartz Iodine Metal Halide Total lumnes 6 x 33 000W 198 000 6 x 220 000W 1 320 000 Illuminated surface 16 500 m2 110 000 m2 Waterproof contro...

Page 10: ...ature meter in the center thereof so that the customer can respect working properties of the oil Some oils can lose properties above or below certain temperatures For water oil and diesel levels of th...

Page 11: ...G SET As shown in the start up procedure described in the instructions of the generating set See Genset manual Extract the legs Fig 3 Put the safety brackets back in again Fig 3 Fig 3 Turn the uppermo...

Page 12: ...ON Mast start control lt allows the control of the mast through two simple maneuver press buttons located at the waterproof and maneuvering shelter Fig 1 Before moving the mast it is necessary to star...

Page 13: ...Fig 3 in order to avoid unexpected movements and mast falls because of a loss of load Fig 3 5 9 SWITCHING ON THE SPOTLIGHTS To switch on the spotlights it was enough with connecting the main switch Fi...

Page 14: ...trol pag 12 6 3 MAIN SWITCH DISCONNECTION Disconnect the main switch in the control and manoeuvring panel 6 4 STOPPING THE GENSET Follow the instructions for the generating set 6 5 DISCONNECTING THE G...

Page 15: ...draulic bottle has to be carried out every time we start the lighting tower The hoses must be checked every time start up and be replaced when necessary In case of blown bulbs it is advisable to use g...

Page 16: ...y Himoinsa In the case of Generating sets it is only applicable to those generating sets that operate together with an manual or automated control panel manufactured or and installed by HIMOINSA The G...

Page 17: ...orage transrportation or installing any kind of use of the equipment over the capacity and limits established by the manufacturer or under conditions different from those recommended failures caused a...

Page 18: ...ly need of the purchaser The present warranty will not be applicable to the following cases When the documentation warranty purchasing invoice maintenance and use manual may have been altered in any w...

Page 19: ...nden con la informaci n disponible en el momento de la impresi n HIMOINSA 2015 Todos los derechos reservados HIMOINSA October 2015 FACTORIES SPAIN FRANCE INDIA CHINA USA BRAZIL SUBSIDIARIES PORTUGAL S...

Reviews: