START UP |
PAG. 11
Once all spotlights are in place connect each one to its corresponding socket
(Fig. 4).
4
3
1
2
5.4 CONNECTING THE GENERATING SET TO TOWER
Once you have verified the connexion and the proper fixing of the spotlights, we
will connect the generating set to the lighting tower. (Fig. 4).
In order to carry out this operation, get the extension cable that is in one of the
side compartments (Fig. 1) and connect one of the ends to the corresponding
power output located in the generating set (Fig. 2) control panel and the other
end to the lighting tower (Fig. 3).
1
2
3
4
5.5 STARTING UP THE GENERATING SET.
As shown in the start up procedure described in the instructions of the generating
set. (See Genset manual).
•
Extract the legs. (Fig. 3)
•
Put the safety brackets back in again. (Fig. 3)
Fig.3
•
Turn the uppermost handle on the telescopic spindle bearings until it
grips there is a certain resistance. In this way one can balance and
fix the tower to the chosen work surface. (Fig. 4)
Fig.4
5.3 INSTALING THE SPOTLIGHTS
Place the supplied spotlights in their corresponding slots, fixing them with the
wingnuts located at the end of the mast.
In order to carry out this operation, unscrew the wingnut and remove the
supporting bracket (Fig. 1). Fit the spotlights (Fig. 2) with the glass upwards,
place the supporting bracket which grips the spotlight mounting, then the wingnut
and tighten it firmly (Fig. 3).
RAMIRENT