(APPENDIX III) DIMENSIONS, WIRING AND MECHANICAL PARTS |
PAGE 87
Signal
Description
Type
Characteristics
SETA
Emergency stop button
Output
Low-level digital input active
PC
Configurable stop
Output
High-level power digital output active
PR
Preheating
Output
High-level power digital output active
ARR
Starting
Output
High-level power digital output active
SAL4
Output 4
Output
High-level power digital output active
+BAT
Positive battery terminal
Power supply Digital outputs supply voltage
SCC
Overload and short circuit
Output
Overload and short circuit relay, C
contact
SCNC
Overload and short circuit
Output
Overload and short circuit relay, NC
contact
SCNA
Overload and short circuit
Output
Overload and short circuit relay, NA
contact
BTC
Fuel transfer pump
Output
Fuel transfer pump relay, C contact
BTNA
Fuel transfer pump
Output
Fuel transfer pump relay, NA contact
CGC
Genset contactor
Output
Genset contactor relay, C contact
CGNC
Genset contactor
Output
Genset contactor relay, NC contact
CGNA
Genset contactor
Output
Genset contactor relay, NA contact
CRC
Network contactor
Output
Network contactor relay, C contact
CRNC
Network contactor
Output
Network contactor relay, NC contact
CRNA
Network contactor
Output
Network contactor relay, NA contact
IL3
Current phase 3
Input
Analogue input for current measurement
IL2
Current phase 2
Input
Analogue input for current measurement
IL1
Current phase 1
Input
Analogue input for current measurement
NIL
Standard current
Input
Analogue input for current measurement
VR3
Network voltage phase 3
Input
Analogue input for voltage measurement
VR2
Network voltage phase 2
Input
Analogue input for voltage measurement
VR1
Network voltage phase 1
Input
Analogue input for voltage measurement
NVR
Neutral network voltage
Input
Analogue input for voltage measurement
VG3
Genset voltage phase 3
Input
Analogue input for voltage measurement
VG2
Genset voltage phase 3
Input
Analogue input for voltage measurement
VG1
Genset voltage phase 3
Input
Analogue input for voltage measurement
NVG
Neutral genset voltage
Input
Analogue input for voltage measurement
Table 5
Measurements module wiring PHG7J
Signal
Description
Type
Characteristics
8÷36 V
Positive battery terminal
Power supply
Control unit supply voltage from 8 to
36V
-BAT
Negative battery terminal
Power supply Control unit supply negative
MAN
Manual
Input
High-level digital input active for start up
CANS
CAN bus screen
Bus
CAN communication
CANL
CANL line CAN bus
Bus
CAN communication
CANH
CANH line CAN bus
Bus
CAN communication
J1939S
J1939 bus screen
Bus
J1939 communication
J1939L
J1939L line J1939 bus
Bus
J1939 communication
J1939H
J1939H line J1939 bus
Bus
J1939 communication
RC
Fuel reserve
Input
Low-level digital input active
BPA
Low oil pressure
Input
Low-level digital input active
ATA
High water temperature
Input
Low-level digital input active
NA
Water level
Input
Low-level digital input active
AE
External start
Input
Low-level digital input active
IA
Start inhibition
Input
Low-level digital input active
PEM
Emergency stop
Input
Low-level digital input active
ENT1
Input 1
Input
Low-level digital input active
ENT2
Input 2
Input
Low-level digital input active
ENT3
Input 3
Input
Low-level digital input active
PCK1
Pick-up
Input
PICK-UP high speed digital input
PCK2
Pick-up
Input
PICK-UP high speed digital input
NC
Fuel level
Input
Analogue input of resistance sensor
P
Pressure
Input
Analogue input of resistance sensor
T
Temperature
Input
Analogue input of resistance sensor
TC
Oil temperature
Input
Analogue input of resistance sensor
DI
Alternator voltage
Input
Analogue input with voltage 0-40V
GND
Mass sensors
Input
Negative for sensors with 2 terminals
D+
Alternator excitation
Output
High-level digital output active
MA
Motor started
Output
High-level digital output active
SAL1
Output 1
Output
High-level digital output active
SAL2
Output 2
Output
High-level digital output active
SAL3
Output 3
Output
High-level digital output active