7
4. Technical data
4. Technical data
Power supply
3 V DC
Type: AA (LR6, AM3, Mignon)
Standard: two alkaline primary cells
Optional: rechargeable NiMh cells
Battery status indicator
Battery display with four segments
showing 100%, 75%, 50% and
25 % charged
All segments deleted = empty battery
Measuring range
0.05 m to 200 m (2 inch to 600 ft)
0.05 m (2 inch) from the front edge
Max. distance resolution 750 m
(2,500 ft)
Typical measuring range without
target plate:
– Drywall panel, white70 m (210 ft)
– Concrete, dry 50 m (150 ft)
– Brick, dry 50 m (150 ft)
The maximum range depends on:
– Reflectivity of the target surface
– Ambient light conditions
In case measurements are not
possible, use the Hilti PDA 50
target plate.
Accuracy
±1.5 mm (±1/16 inch) is typical
for individual and continuous
measurements **
** The measuring accuracy is
affected by ± (1.5 mm + 20 ppm) /
± (1/16 inch + 20 ppm) due to
atmospheric conditions. This affect is
typically noticeable at distances >
100 m (> 300 ft).
Smallest unit displayed
1 mm (1/16 inch)
Beam diameter
< 6mm @ 10m (< 0,2 in @ 30 ft)
< 30mm @ 50m (< 1,2 in @ 150 ft)
< 60mm @ 100m (< 2,4 in @ 300 ft)
Basic operating modes
Single measurement
Continuous measurement
Calculation / Functions
Display
Illuminated liquid-crystal display
showing operating status and battery
status
Laser
Visible, 620 – 690 nm, laser class 2
(IEC60825-1: 1993 + A1: 1997+ A2:
2001/ DIN EN60825-1: 2003;
CFR 21 § 1040 [FDA]
output power: < 1mW
Automatic time-out
Laser 1 min.
Range meter: 10 min.
Battery life at 25°C (77°F)
Max. number of measurements
with single set of batteries.
Alkaline:
15’000 - 20’000
NiMH:
8’000 - 10’000
Operating temperature
- 10°C…+ 50°C (14°F… 122°F)
Storage temperature
- 30°C…+ 70°C (- 22°F… 158°F)
Protection class
Dust and splash-proof, IP 54 as
per IEC529 standard
Weight
220 g / 0,48 lb (without batteries)
Dimensions
120 (L) x 65 (B) x 28 (H) mm
4,7˝ (L) x 2,5˝ (B) x 1,1˝ (H)
Printed: 07.07.2013 | Doc-Nr: PUB / 5070013 / 000 / 00